Preconfined Circular Steel Tubed Concrete under Axial Compression

作者: Sittichai Seangatith , Nantika Namvijitr

DOI: 10.1007/978-3-642-36691-8_88

关键词: Steel jacketLarge deformationCompressive strengthLinear elasticityStrain softeningComposite materialAxial compressionMaterials scienceDuctilityCompressive load

摘要: This study reports the experimental results on behaviors and modes of failure circular concrete specimens preconfined with steel jackets. A total 30 were tested in this study. The dimensions 150 mm diameters 300 height. main variables ultimate compressive strength concrete, thickness jacket preconfining pressure. From tests, it was found that ductility tubed are increased significantly compared to reference specimens, depending used have a linear elastic behavior up or 50-70% their first maximum load. Then, is nonlinear form strain softening very large deformation before failure.