Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument.

作者: Kwang-kyoun Kim , Stephen M. Howell , Ye-yeon Won

DOI: 10.3349/YMJ.2020.61.3.201

关键词: Distal femurTotal knee arthroplastyDeformityArticular surfaceOrthodonticsKinematicsRobotic systemsKnee kinematicsComputer sciencePatient specific

摘要: Kinematically aligned total knee arthroplasty (TKA) is a new alignment technique. Kinematic corrects arthritic deformity to the patient's constitutional in order position femoral and tibial components, as well restore knee's natural tibial-femoral articular surface, alignment, laxity. motion moves around single flexion-extension axis of distal femur, passing through center cylindrically shaped posterior condyles. Since it can be difficult locate cylindrical with conventional instrument, patient-specific instrument (PSI) used align kinematic axes. PSI was recently introduced technology goal improving accuracy operative technique, avoiding practical issues related complexity navigation robotic system, such costs higher number personnel required. There are several limitations implement kinematically TKA implant for mechanical alignment. Therefore, important design an optimal shape restoring kinematics that might improve patient-reported satisfaction function.

参考文章(52)
Donald Eckhoff, Craig Hogan, Laura DiMatteo, Mitch Robinson, Joel Bach, Difference between the epicondylar and cylindrical axis of the knee. Clinical Orthopaedics and Related Research. ,vol. 461, pp. 238- 244 ,(2007) , 10.1097/BLO.0B013E318112416B
Wilhelm Eduard Weber, Eduard Weber, Mechanics of the Human Walking Apparatus ,(1991)
Emily J. Miller, Mark W. Pagnano, Kenton R. Kaufman, Tibiofemoral alignment in posterior stabilized total knee arthroplasty: Static alignment does not predict dynamic tibial plateau loading Journal of Orthopaedic Research. ,vol. 32, pp. 1068- 1074 ,(2014) , 10.1002/JOR.22644
Kathryn M Coughlin, Stephen J Incavo, David L Churchill, Bruce D Beynnon, Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. Journal of Arthroplasty. ,vol. 18, pp. 1048- 1055 ,(2003) , 10.1016/S0883-5403(03)00449-2
Anne M Hollister, Sanjay Jatana, Anoop K Singh, William W Sullivan, Andrei G Lupichuk, None, The axes of rotation of the knee. Clinical Orthopaedics and Related Research. ,vol. 290, pp. 259- 268 ,(1993) , 10.1097/00003086-199305000-00033
Tilman Pfitzner, Eric Röhner, Bernd Preininger, Carsten Perka, Georg Matziolis, Femur Positioning in Navigated Total Knee Arthroplasty Orthopedics. ,vol. 35, pp. 45- 49 ,(2012) , 10.3928/01477447-20120919-57
Masahiro Ishikawa, Shinichi Kuriyama, Hiromu Ito, Moritoshi Furu, Shinichiro Nakamura, Shuichi Matsuda, Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design Knee. ,vol. 22, pp. 206- 212 ,(2015) , 10.1016/J.KNEE.2015.02.019
Arnd Steinbrück, Christian Schröder, Matthias Woiczinski, Andreas Fottner, Peter E. Müller, Volkmar Jansson, The effect of trochlea tilting on patellofemoral contact patterns after total knee arthroplasty: an in vitro study. Archives of Orthopaedic and Trauma Surgery. ,vol. 134, pp. 867- 872 ,(2014) , 10.1007/S00402-014-1956-1
Robert B. Bourne, Bert M. Chesworth, Aileen M. Davis, Nizar N. Mahomed, Kory D. J. Charron, Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not? Clinical Orthopaedics and Related Research®. ,vol. 468, pp. 57- 63 ,(2010) , 10.1007/S11999-009-1119-9
Daniel D. Rhoads, Philip C. Noble, Jeffrey D. Reuben, Ormonde M. Mahoney, Hugh S. Tullos, The effect of femoral component position on patellar tracking after total knee arthroplasty Clinical Orthopaedics and Related Research. ,vol. 260, pp. 43- 51 ,(1990) , 10.1097/00003086-199011000-00009