摘要: This paper presents a reference current generation scheme for improved dynamic performance of doubly fed induction generator (DFIG) subjected to unbalanced grid voltage. The power and torque oscillations induced due the unbalance in voltage are minimized using additional compensatory terms currents. focus is on estimating currents control implementation without need dual vector control. Real reactive implemented positive ${\mbi {d - q}}$ frame stator flux-oriented rotor-side converter (RSC) controlled enable effective reduction active power. dc-link oscillation grid-side factor maintained unity (GSC). Unlike previously reported techniques, proposed enables torque, active, power, voltage, all single target. DFIG investigated consideration with Indian Electricity Grid Code (IEGC). Numerical simulations carried out system computer aided design/electromagnetic transients including direct (PSCAD/EMTDC) laboratory 3-hp test setup. results establish that notably enhanced scheme.

参考文章(20)
Yong Liao, Hui Li, Jun Yao, Kai Zhuang, Operation and control of a grid-connected DFIG-based wind turbine with series grid-side converter during network unbalance Electric Power Systems Research. ,vol. 81, pp. 228- 236 ,(2011) , 10.1016/J.EPSR.2010.09.002
MA Asha Rani, A Karthikeyan, C Nagamani, Decoupled control of doubly-fed-induction generator under unbalanced grid voltage with modified reference generation international conference on power energy and control. pp. 420- 425 ,(2013) , 10.1109/ICPEC.2013.6527693
Jiabing Hu, Yikang He, Lie Xu, Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance Electric Power Systems Research. ,vol. 80, pp. 847- 856 ,(2010) , 10.1016/J.EPSR.2009.12.010
Y. Wang, L. Xu, B.W. Williams, Compensation of network voltage unbalance using doubly fed induction generator-based wind farms Iet Renewable Power Generation. ,vol. 3, pp. 12- 22 ,(2009) , 10.1049/IET-RPG:20080007
Lie Xu, Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance IEEE Transactions on Power Electronics. ,vol. 23, pp. 1041- 1049 ,(2008) , 10.1109/TPEL.2008.921157
Lie Xu, Enhanced Control and Operation of DFIG-Based Wind Farms During Network Unbalance IEEE Transactions on Energy Conversion. ,vol. 23, pp. 1073- 1081 ,(2008) , 10.1109/TEC.2008.2001452
Yi Zhou, P. Bauer, J.A. Ferreira, J. Pierik, Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition IEEE Transactions on Energy Conversion. ,vol. 24, pp. 240- 246 ,(2009) , 10.1109/TEC.2008.2011833
Ehsan Javan, Ahmad Darabi, A new control strategy of DFIG-based wind turbines under unbalanced grid voltage conditions the power electronics, drive systems & technologies conference. pp. 175- 180 ,(2011) , 10.1109/PEDSTC.2011.5742412
R. Datta, V.T. Ranganathan, Decoupled control of active and reactive power for a grid-connected doubly-fed wound rotor induction machine without position sensors ieee industry applications society annual meeting. ,vol. 4, pp. 2623- 2630 ,(1999) , 10.1109/IAS.1999.799208