Recent Advances in Neuroanesthesia Monitoring—Transcranial Doppler Ultrasonography and Jugular Bulb Venous Oximetry

作者: Arthur M. Lam

DOI: 10.1007/978-94-011-5774-2_6

关键词: Jugular bulbInternal medicineCardiologyTranscranial Doppler ultrasonographyOxidative metabolismMean arterial pressureCarotid endarterectomyCerebral blood flowMedicineBlood flow

摘要: With the introduction of transcranial Doppler ultrasonography and jugular bulb venous oximetry, it is now possible to monitor blood flow oxidative metabolism brain clinically. Although both modalities have significant limitations, they nevertheless represent important advances in clinical neuroanesthesia monitoring.

参考文章(75)
A. Helden, G.-H. Schneider, A. Unterberg, W. R. Lanksch, Monitoring of jugular venous oxygen saturation in comatose patients with subarachnoid haemorrhage and intracerebral haematomas. Acta Neurochirurgica. ,vol. 59, pp. 102- 106 ,(1993) , 10.1007/978-3-7091-9302-0_18
K.-H. Chan, N. M. Dearden, J. D. Miller, Transcranial Doppler-Sonography in Severe Head Injury Acta Neurochirurgica. ,vol. 59, pp. 81- 85 ,(1993) , 10.1007/978-3-7091-9302-0_14
R. Bullock, L. Stewart, C. Rafferty, G. M. Teasdale, Continuous Monitoring of Jugular Bulb Oxygen Saturation and the Effect of Drugs Acting on Cerebral Metabolism Acta Neurochirurgica. ,vol. 59, pp. 113- 118 ,(1993) , 10.1007/978-3-7091-9302-0_20
M. Shigemori, N. Kikuchi, T. Tokutomi, S. Ochiai, K. Harada, T. Kikuchi, S. Kuramoto, Monitoring of Severe Head-Injured Patients with Transcranial Doppler (TCD) Ultrasonography Acta Neurochirurgica. ,vol. 55, pp. 6- 7 ,(1992) , 10.1007/978-3-7091-9233-7_2
MARK G. GOETTING, GREGORY PRESTON, Jugular bulb catheterization: experience with 123 patients. Critical Care Medicine. ,vol. 18, pp. 1220- 1223 ,(1990) , 10.1097/00003246-199011000-00006
Arthur M. Lam, Teresa Slee Mayberg, Calvin C. Eng, Jeremy O. Cooper, Kenneth L. Bachenberg, Terri L. Mathisen, Nitrous oxide-isoflurane anesthesia causes more cerebral vasodilation than an equipotent dose of isoflurane in humans. Anesthesia & Analgesia. ,vol. 78, pp. 462- 468 ,(1994) , 10.1213/00000539-199403000-00007
Holly C. Gunn, Basil F. Matta, Arthur M. Lam, Teresa S. Mayberg, Accuracy of continuous jugular bulb venous oximetry during intracranial surgery. Journal of Neurosurgical Anesthesiology. ,vol. 7, pp. 174- 177 ,(1994) , 10.1097/00008506-199507000-00003
A Dahl, D Russell, R Nyberg-Hansen, K Rootwelt, Effect of nitroglycerin on cerebral circulation measured by transcranial Doppler and SPECT. Stroke. ,vol. 20, pp. 1733- 1736 ,(1989) , 10.1161/01.STR.20.12.1733
Dennis D. Doblar, Y. C. Lim, Luc Frenette, Steven Poplawski, Dinesh Ranjan, Jamie Ronderos, The effect of acute hypocapnia on middle cerebral artery transcranial Doppler velocity during orthotopic liver transplantation: changes at reperfusion. Anesthesia & Analgesia. ,vol. 80, pp. 1194- 1198 ,(1995) , 10.1097/00000539-199506000-00022
M. G. Goetting, G. Preston, Jugular bulb catheterization does not increase intracranial pressure. Intensive Care Medicine. ,vol. 17, pp. 195- 198 ,(1991) , 10.1007/BF01709876