作者: Tiejun Xu , Shenghong Huang , Han Xie , Yuntao Song , Ping Zhan
DOI: 10.1088/1009-0630/13/6/24
关键词: Heat transfer 、 Thermal contact conductance 、 Communication channel 、 Welding 、 Heat sink 、 Sample (graphics) 、 Numerical analysis 、 Mechanical engineering 、 Materials science 、 Tube (fluid conveyance)
摘要: Considering utilization of the original chromium-bronze material, two processing techniques including hydraulic expansion and high temperature vacuum welding were proposed for optimization heat-sink structure in EAST. The heat transfer performance with or without cooling tube was calculated different types connection between compared by conducting a special test. It is shown from numerical analysis that diameter channel can be reduced 12 mm to 10 mm. Compared sample, thermal contact resistance sample reduce 10%, while 20% sample. However, technique more complicated expensive than technique. Both prototype should further considered