Electrochemical Behavior and Determination of Phenylephrine at the Multi-Walled Carbon Nanotubes/ionic Liquid Nanocomposite Modified Electrode in the Presence of Acetaminophen

作者: B. Habibi , Z. Ayazi , Firooz Zalvand

DOI:

关键词: Differential pulse voltammetryElectrodeElectrochemistryComposite materialNuclear chemistryCyclic voltammetryNanocompositeDetection limitChronoamperometryIonic liquidMaterials science

摘要: A simple and high sensitive electrochemical method was developed for determination of phenylephrine (PHE) in the presence acetaminophen (AC) at carbon-ceramic electrode modified by multi-walled carbon nanotubes/ionic liquid nanocomposite (MWCNTs/IL/CCE). Cyclic voltammetry (CV) differential pulse (DPV) chronoamperometry methods were used studies measurements, respectively. The obtained results show that MWCNTs/IL/CCE exhibited electrocatalytic activity towards oxidation PHE. Under optimum conditions, anodic peak current DPV is linear to PHE concentration over ranges 3×10-7 M-100×10-6 M with a correlation coefficient 0.998 detection limit 1.7×10-7 M. also simultaneous AC same conditions. stability, reproducibility repeatability investigated relative standard deviations has excellent repeatability. Finally, effectively applied some real samples without any interference.

参考文章(50)
Vinod Kumar Gupta, Naveen Mergu, Lokesh Kumar Kumawat, Ashok Kumar Singh, A reversible fluorescence "off-on-off" sensor for sequential detection of aluminum and acetate/fluoride ions. Talanta. ,vol. 144, pp. 80- 89 ,(2015) , 10.1016/J.TALANTA.2015.05.053
Razie Bavandpour, Hassan Karimi-Maleh, Mohammad Asif, Vinod Kumar Gupta, Necip Atar, Maryam Abbasghorbani, Liquid phase determination of adrenaline uses a voltammetric sensor employing CuFe2O4 nanoparticles and room temperature ionic liquids Journal of Molecular Liquids. ,vol. 213, pp. 369- 373 ,(2016) , 10.1016/J.MOLLIQ.2015.07.054
V.K. Gupta, A.K. Jain, P. Kumar, S. Agarwal, G. Maheshwari, Chromium(III)-selective sensor based on tri-o-thymotide in PVC matrix Sensors and Actuators B-chemical. ,vol. 113, pp. 182- 186 ,(2006) , 10.1016/J.SNB.2005.02.046
Hongtao Liu, Ping He, Zhiying Li, Chunyan Sun, Lihong Shi, Yang Liu, Guoyi Zhu, Jinghong Li, An ionic liquid-type carbon paste electrode and its polyoxometalate-modified properties Electrochemistry Communications. ,vol. 7, pp. 1357- 1363 ,(2005) , 10.1016/J.ELECOM.2005.09.018
Vinod Kumar Gupta, B. Sethi, R.A. Sharma, Shilpi Agarwal, Arvind Bharti, Mercury selective potentiometric sensor based on low rim functionalized thiacalix [4]-arene as a cationic receptor Journal of Molecular Liquids. ,vol. 177, pp. 114- 118 ,(2013) , 10.1016/J.MOLLIQ.2012.10.008
Vinod Kumar Gupta, Suresh Jain, Sudeshna Chandra, Chemical sensor for lanthanum(III) determination using aza-crown as ionophore in poly(vinyl chloride) matrix Analytica Chimica Acta. ,vol. 486, pp. 199- 207 ,(2003) , 10.1016/S0003-2670(03)00506-3
Michel Armand, Frank Endres, Douglas R. MacFarlane, Hiroyuki Ohno, Bruno Scrosati, Ionic-liquid materials for the electrochemical challenges of the future. Nature Materials. ,vol. 8, pp. 621- 629 ,(2009) , 10.1038/NMAT2448
Vinod Kumar Gupta, Ashok Kumar Singh, Lokesh Kumar Kumawat, Thiazole Schiff base turn-on fluorescent chemosensor for Al3+ ion Sensors and Actuators B-chemical. ,vol. 195, pp. 98- 108 ,(2014) , 10.1016/J.SNB.2013.12.092
O. Lev, Z. Wu, S. Bharathi, V. Glezer, A. Modestov, J. Gun, L. Rabinovich, S. Sampath, Sol−Gel Materials in Electrochemistry Chemistry of Materials. ,vol. 9, pp. 2354- 2375 ,(1997) , 10.1021/CM970367B