The change in internal aberrations following myopic corneal laser refractive surgery

作者: Colm McAlinden , Jonathan E Moore , None

DOI: 10.1007/S00417-010-1459-X

关键词:

摘要: Background In virgin eyes, the internal aberrations compensate corneal aberrations, and it has been suggested that compensation may be feedback-driven developmental, with active or passive adaptive mechanisms potentially responsible for aberration auto-compensation. The purpose of this study is to investigate higher order (HOA) following laser in situ keratomileusis (LASIK).

参考文章(47)
Alejandro Cerviño, Sarah L Hosking, Robert Montes-Mico, Keith Bates, Clinical Ocular Wavefront Analyzers Journal of Refractive Surgery. ,vol. 23, pp. 603- 616 ,(2007) , 10.3928/1081-597X-20070601-12
Jackson Barreto Jr, Marcelo V Netto, Alberto Cigna, Samir Bechara, Newton Kara-José, Precision of higher order aberration repeatability with NIDEK OPD-scan retinoscopic aberrometry. Journal of Refractive Surgery. ,vol. 22, ,(2006) , 10.3928/1081-597X-20061102-06
Mike P Holzer, Susanne Goebels, Gerd U Auffarth, Precision of NIDEK OPD-scan measurements. Journal of Refractive Surgery. ,vol. 22, ,(2006) , 10.3928/1081-597X-20061102-02
Thomas Young, On the Mechanism of the Eye Philosophical Transactions. ,(1801)
Sergio Barbero, Susana Marcos, Lourdes Llorente, Jesús Merayo-Lloves, Optical response to LASIK surgery for myopia from total and corneal aberration measurements. Investigative Ophthalmology & Visual Science. ,vol. 42, pp. 3349- 3356 ,(2001)
Do-Hyung Lee, Sejung Seo, Kui Won Jeong, Soo-Cheol Shin, John A. Vukich, Early spatial changes in the posterior corneal surface after laser in situ keratomileusis. Journal of Cataract and Refractive Surgery. ,vol. 29, pp. 778- 784 ,(2003) , 10.1016/S0886-3350(02)01842-4
A Tomlinson, R P Hemenger, R Garriott, Method for estimating the spheric aberration of the human crystalline lens in vivo. Investigative Ophthalmology & Visual Science. ,vol. 34, pp. 621- 629 ,(1993)
Lourdes Llorente, Sergio Barbero, Jesus Merayo, Susana Marcos, Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia. Journal of Refractive Surgery. ,vol. 20, pp. 203- 216 ,(2004) , 10.3928/1081-597X-20040501-03
Alejandro Cerviño, Sarah L. Hosking, Robert Montés-Micó, Comparison of higher order aberrations measured by NIDEK OPD-Scan dynamic skiascopy and Zeiss WASCA Hartmann-Shack aberrometers. Journal of Refractive Surgery. ,vol. 24, pp. 790- 796 ,(2008) , 10.3928/1081597X-20081001-04