作者: Xinyan Shi , Mingqiang Ma , Chengbo Lian , Dawei Zhu
DOI: 10.1016/J.POLYMERTESTING.2013.06.010
关键词:
摘要: Abstract The effects of dynamic fatigue frequency, temperature and number cycles on the adhesion rubber to steel cord in a carcass recipe were examined. A new test method with special rubber/steel specimens was developed for measurements which carried out De Mattia Rubber Flexometer. It found that “pull-out forces” decreased increase but first increased then increasing cycles. failure mainly occurred phase rather than at interface. covered “pulled-out” after appeared form screw thread greater pull-out force corresponded more uniform clearer threads remaining cord. Steel an outer wrapping wire had static better fatigue; some contact point wrapped main wires. coverage along twist direction wire. SEM indicated un-dispersed filler agglomerates may initiate failure.