Influence of axial length of normal eyes on PERG.

作者: Rudy Hidajat , Jan Mclay , Celeste Burley , Mark Elder , Jason Morton

DOI: 10.1023/A:1026282425885

关键词:

摘要: The influence of the axial length (AL) eye on flash electroretinogram (ERG) responses has been well established in literature, suggesting an association between ERG abnormalities with myopia (AL > 25 mm). aim our present study was to determine whether AL normal eyes can also pattern (PERG) subjects. Thirty-nine volunteers were subjected PERG measurements following standard set by International Society for Clinical Electrophysiology Vision (ISCEV). eyeball measured using a TOMEY ultrasonic A scanner. Each volunteer had complete ophthalmic examination including visual acuity, refraction, intraocular pressure, field, colour vision, orthoptic assessment and retinal photographs best corrected acuity 6/9 or better. Only one from each 39 included statistical analysis results. group mean P50 amplitude 3.8 ± 1.1 SD μV. range 21.8 25.7 mm (mean = 23.8 1.0 Overall findings obtained this investigation indicate significant correlation (Spearman rank coefficient r −0.413, p < 0.01). accounts 17% variance observed values. This confirms current hypothesis that is inversely related means should be considered when interpreting amplitudes.

参考文章(9)
Hidehito Kawabata, Emiko Adachi-Usami, Multifocal electroretinogram in myopia. Investigative Ophthalmology & Visual Science. ,vol. 38, pp. 2844- 2851 ,(1997)
Bach, Hawlina, Holder, Marmor, Meigen, Vaegan, Miyake, Standard for pattern electroretinography Documenta Ophthalmologica. ,vol. 101, pp. 11- 18 ,(2000) , 10.1023/A:1002732114721
Carol A. Westall, Harjinder S. Dhaliwal, Carole M. Panton, Dayle Sigesmund, Alex V. Levin, Ken K. Nischal, Elise Héon, Values of electroretinogram responses according to axial length. Documenta Ophthalmologica. ,vol. 102, pp. 115- 130 ,(2001) , 10.1023/A:1017535207481
I. Perlman, E. Meyer, T. Haim, S. Zonis, Retinal function in high refractive error assessed electroretinographically. British Journal of Ophthalmology. ,vol. 68, pp. 79- 84 ,(1984) , 10.1136/BJO.68.2.79
Michael F. Marmor, Geoffrey B. Arden, Sven-Erik Nilsson, Eberhart Zrenner, , Standard for clinical electroretinography Documenta Ophthalmologica. ,vol. 107, pp. 816- 819 ,(1989) , 10.1007/BF00154486
Michael F. Marmor, Standard for Clinical Electroretinography Archives of Ophthalmology. ,vol. 107, pp. 816- 819 ,(1989) , 10.1001/ARCHOPHT.1989.01070010838024
S. A. Burns, Ju-Fun Chen, K. K. Kwong, A. E. Elsner, A. B. Fulton, R. M. Hansen, P. L. Lou, The effect of eye shape on retinal responses Clinical vision sciences. ,vol. 7, pp. 521- 530 ,(1992)