Probabilistic safety assessment of the dual-cooled waste transmutation blanket for the FDS-I

作者: L. Hu , Y. Wu

DOI: 10.1016/J.FUSENGDES.2005.08.091

关键词:

摘要: … will stop if the EPS does not promptly function, including the ESS system in the current FDS-I … Note that the safety systems ESS, EPS and EFD are simultaneous when the signal of LOFA …

参考文章(4)
Y. Wu, S. Zheng, X. Zhu, W. Wang, H. Wang, S. Liu, Y. Bai, H. Chen, L. Hu, M. Chen, Huang Q., D. Huang, S. Zhang, J. Li, D. Chu, J. Jiang, Y. Song, Conceptual design of the fusion-driven subcritical system FDS-I Fusion Engineering and Design. ,vol. 81, pp. 1305- 1311 ,(2006) , 10.1016/J.FUSENGDES.2005.10.015
Ruxandra P. Golinescu, Florinel Morosan, Mujid S. Kazimi, A probabilistic methodology for the design of radiological confinement of tokamak reactors Reliability Engineering & System Safety. ,vol. 58, pp. 275- 296 ,(1997) , 10.1016/S0951-8320(97)00106-3
Y. Bai, H. Chen, Y. Ke, W.H. Wang, S.L. Zheng, Preliminary transient thermal analysis for safety of the dual-cooled waste transmutation blanket for the FDS-I Fusion Engineering and Design. ,vol. 81, pp. 1397- 1401 ,(2006) , 10.1016/J.FUSENGDES.2005.09.080