Half-life of 90Sr — measurement and critical review

作者: M.J. Woods , S.E.M. Lucas

DOI: 10.1016/S0168-9002(96)80045-3

关键词:

摘要: Abstract Recent evaluations of the half-life 90Sr have demonstrated variable quality available experimental data which has prevented estimation and adoption a value that commands confidence. In an attempt to reduce uncertainty in acceptable level, decay source been followed for over six years at NPL. The equipment comprised matching, re-entrant, high-pressure ionization chambers long-lived reference non-random effects. technique is described together with statistical procedure used analyse measured data. A was determined estimate associated uncertainties. new evaluation made, taking account NPL other recent measurements. Particular attention paid techniques produce uncertainties attributed them. An objective conducted recommended 10 516 ± 21 days.

参考文章(4)
A E Kochin, M G Kuzmina, I A Sokolova, P L Merson, Measurement of the 90Sr Half-life Metrologia. ,vol. 26, pp. 203- 204 ,(1989) , 10.1088/0026-1394/26/3/006
D. M. Wiles, R. H. Tomlinson, THE HALF-LIFE OF Sr90 Canadian Journal of Physics. ,vol. 33, pp. 133- 137 ,(1955) , 10.1139/P55-017
Robert H Martin, Kerry I.W Burns, John G.V Taylor, A measurement of the half-life of 90Sr Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 339, pp. 158- 163 ,(1994) , 10.1016/0168-9002(94)91797-3