Measurement of micron level distortions in a macroscopic cylindrical object from x-ray CT images

作者: R.B. Horney , A. Gibson , I.D. Svalbe

DOI: 10.1016/J.NDTEINT.2011.12.006

关键词:

摘要: Abstract A technique for the measurement or tracking of fine distortion in macroscopic objects nominally circular section is described and assessed. Distortions order several microns have been measured a 14 cm diameter, thick-walled polymethyl methacrylate (PMMA Perspex) cylinder by location multiple edge points object its x-ray CT images using circle-PLUS subpixel detection procedure. The was deformed compressing it along diameter over total range 340 μ m (0.7 pixel image) 10 steps. successive wall deflections direction compression, corresponding perpendicular direction, were calculated from obtained GE Lightspeed medical scanner. shifts compared directly with mechanical measurements micrometer. minimum detectable shift 0.033 pixel 1/30th pixel ( 16 ) image verified measurement. procedure should be applicable to both precision industrial clinical such as vessel bone dimensions applications requiring precise organ size, shape position determination. not restricted could also readily applied optical MRI data.

参考文章(39)
Robert M. Haralick, A Facet Model for Image Data: Regions, Edges, and Texture Digital Image Processing. pp. 337- 356 ,(1981) , 10.1007/978-94-009-8543-8_20
Leslie Fox, I B Parker, Chebyshev polynomials in numerical analysis ,(1970)
I.T. Young, P.W. Verbeek, H. Netten, Exact reconstruction of sampled images multidimensional signal processing workshop. pp. 212- ,(1989) , 10.1109/MDSP.1989.97127
P.W Verbeek, A class of sampling-error free measures in oversampled band-limited images Pattern Recognition Letters. ,vol. 3, pp. 287- 292 ,(1985) , 10.1016/0167-8655(85)90009-1
A. Saragaglia, C. Fetita, P. Y. Brillet, F. Prêteux, P. A. Grenier, Airway wall thickness assessment: a new functionality in virtual bronchoscopy investigation SPIE Conference on Medical Imaging'2007; Physiology, Function, and Structure from Medical Images. ,vol. 6511, ,(2007) , 10.1117/12.709532
Shuai-jun Peng, Zhi-fang Wu, Research on the CT image reconstruction of steel tube section from few projections Ndt & E International. ,vol. 42, pp. 435- 440 ,(2009) , 10.1016/J.NDTEINT.2009.01.014
Catalin Fetita, Pierre-Yves Brillet, Françoise J. Prêteux, Morpho-geometrical approach for 3D segmentation of pulmonary vascular tree in multi-slice CT Proceedings of SPIE. ,vol. 7259, ,(2009) , 10.1117/12.811637
Randolf Hanke, Theobald Fuchs, Norman Uhlmann, X-ray based methods for non-destructive testing and material characterization Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 591, pp. 14- 18 ,(2008) , 10.1016/J.NIMA.2008.03.016
K. Edalati, N. Rastkhah, A. Kermani, M. Seiedi, A. Movafeghi, The use of radiography for thickness measurement and corrosion monitoring in pipes International Journal of Pressure Vessels and Piping. ,vol. 83, pp. 736- 741 ,(2006) , 10.1016/J.IJPVP.2006.07.010