Very efficient speckle contrast reduction realized by moving diffuser device

作者: Shigeo Kubota , Joseph W. Goodman

DOI: 10.1364/AO.49.004385

关键词:

摘要: Speckle noise reduction is best tested on a precise speckle contrast measurement bench, which should be able to measure 100% in fully developed as well the smallest (for example, less than 10%) after its reduction. On such test we have measured very efficient by temporal averaging using moving diffuser tuning fork, vibrates at 100Hz over 60μm amplitude, distance that three times surface roughness correlation length of diffuser.

参考文章(9)
Joseph W. Goodman, Introduction to Fourier optics ,(1968)
David M. Bloom, Grating Light Valve: revolutionizing display technology electronic imaging. ,vol. 3013, pp. 165- 171 ,(1997) , 10.1117/12.273868
H. Fujii, T. Asakura, Effect of surface roughness on the statistical distribution of image speckle intensity Optics Communications. ,vol. 11, pp. 35- 38 ,(1974) , 10.1016/0030-4018(74)90327-7
Jahja I. Trisnadi, Speckle contrast reduction in laser projection displays electronic imaging. ,vol. 4657, pp. 131- 137 ,(2002) , 10.1117/12.463781
Jahja I. Trisnadi, Hadamard speckle contrast reduction. Optics Letters. ,vol. 29, pp. 11- 13 ,(2004) , 10.1364/OL.29.000011
L. Mandel, Phenomenological Theory of Laser Beam Fluctuations and Beam Mixing Physical Review. ,vol. 138, pp. B753- B762 ,(1965) , 10.1103/PHYSREV.138.B753
J. M. Elson, J. M. Bennett, Relation between the angular dependence of scattering and the statistical properties of optical surfaces Journal of the Optical Society of America. ,vol. 69, pp. 31- 47 ,(1979) , 10.1364/JOSA.69.000031
Joseph W. Goodman, Statistical Optics ,(1985)