Understanding the importance of IOP variables in glaucoma: a systematic review.

作者: Marla B. Sultan , Steven L. Mansberger , Paul P. Lee

DOI: 10.1016/J.SURVOPHTHAL.2009.05.001

关键词:

摘要: Glaucoma is one of the leading causes visual impairment and blindness. Lowering intraocular pressure (IOP) only proven means to slow or halt disease progression among those at higher risk developing glaucoma with early moderate more advanced glaucoma. Recent publications have highlighted potential for increased rates likelihood worsening larger IOP swings within defined time periods. The purpose this systematic, comprehensive review analysis literature was assess state knowledge in area changes over impact such on treatment. Current indicates that a random measurement poor surrogate levels throughout day across visits. We address several key questions: 1) What best way measure IOP? 2) Should multiple measurements be performed office (short-term fluctuation)? 3) Is night required? 4) clinicians begin long-term fluctuation patients under stable treatment (across days visits)? 5) therapy choices influenced by properties different options relative short- fluctuation?

参考文章(134)
Gregory S Horowitz, Julie Byles, John Lee, Catherine D'Este, Comparison of the Tono-Pen and Goldmann tonometer for measuring intraocular pressure in patients with glaucoma. Clinical and Experimental Ophthalmology. ,vol. 32, pp. 584- 589 ,(2004) , 10.1111/J.1442-9071.2004.00907.X
Nicola Orzalesi, Luca Rossetti, Andrea Bottoli, Elena Fumagalli, Paolo Fogagnolo, None, The Effect of Latanoprost, Brimonidine, and a Fixed Combination of Timolol and Dorzolamide on Circadian Intraocular Pressure in Patients With Glaucoma or Ocular Hypertension Archives of Ophthalmology. ,vol. 121, pp. 453- 457 ,(2003) , 10.1001/ARCHOPHT.121.4.453
Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, Julian Garcia-Sanchez, Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Investigative Ophthalmology & Visual Science. ,vol. 47, pp. 4410- 4414 ,(2006) , 10.1167/IOVS.06-0158
David Miller, THE RELATIONSHIP BETWEEN DIURNAL TENSION VARIATION AND THE WATER-DRINKING TEST. American Journal of Ophthalmology. ,vol. 58, pp. 243- 247 ,(1964) , 10.1016/0002-9394(64)91571-5
R Susanna, RM Vessani, L Sakata, LC Zacarias, M Hatanaka, The relation between intraocular pressure peak in the water drinking test and visual field progression in glaucoma British Journal of Ophthalmology. ,vol. 89, pp. 1298- 1301 ,(2005) , 10.1136/BJO.2005.070649
Joel S. Schuman, A 1-Year Study of Brimonidine Twice Daily in Glaucoma and Ocular Hypertension Archives of Ophthalmology. ,vol. 115, pp. 847- 852 ,(1997) , 10.1001/ARCHOPHT.1997.01100160017002
Archana Bhan, Jonathan Bhargava, Stephen A Vernon, Sarah Armstrong, Kanchan Bhan, Louis Tong, Velota Sung, Repeatability of ocular blood flow pneumotonometry Ophthalmology. ,vol. 110, pp. 1551- 1554 ,(2003) , 10.1016/S0161-6420(03)00492-5
Yaniv Barkana, Sarah Anis, Jeffrey Liebmann, Celso Tello, Robert Ritch, Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With Glaucoma Archives of Ophthalmology. ,vol. 124, pp. 793- 797 ,(2006) , 10.1001/ARCHOPHT.124.6.793
PA Tonnu, T Ho, T Newson, A El Sheikh, K Sharma, E White, C Bunce, D Garway-Heath, The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry British Journal of Ophthalmology. ,vol. 89, pp. 851- 854 ,(2005) , 10.1136/BJO.2004.056622