Measuring flexion in knee arthroplasty patients.

作者: John Z Edwards , Kenneth A Greene , Robert S Davis , Mark W Kovacik , Donald A Noe

DOI: 10.1016/J.ARTH.2003.12.001

关键词:

摘要: … knee radiograph then was taken and the flexion angle was measured from the radiograph by 2 different … were greater than 5 different from the true degree of knee flexion. Of the visual …

参考文章(12)
Anthony Adili, Mohit Bhandari, Danielle Petruccelli, Justin de Beer, Sequential bilateral total knee arthroplasty under 1 anesthetic in patients > or = 75 years old: complications and functional outcomes. Journal of Arthroplasty. ,vol. 16, pp. 271- 278 ,(2001) , 10.1054/ARTH.2001.21495
Douglas A. Dennis, Richard D. Komistek, James B. Stiehl, Scott A. Walker, Kendall N. Dennis, Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions. Journal of Arthroplasty. ,vol. 13, pp. 748- 752 ,(1998) , 10.1016/S0883-5403(98)90025-0
Andrew L. Chen, Mohammad Mujtaba, Joseph D. Zuckerman, Gerard K. Jeong, Thomas N. Joseph, Kevin Wright, Paul E. Di Cesare, Midterm clinical and radiographic results with the genesis I total knee prosthesis. Journal of Arthroplasty. ,vol. 16, pp. 1055- 1062 ,(2001) , 10.1054/ARTH.2001.27667
Lucie Brosseau, Michel Tousignant, Julie Budd, Nathalie Chartier, Louise Duciaume, Sherry Plamondon, Joseph P O'Sullivan, Shayne O'Donoghue, Suzanne Balmer, Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects. Physiotherapy Research International. ,vol. 2, pp. 150- 166 ,(1997) , 10.1002/PRI.97
Christopher M. Callahan, Patient Outcomes Following Tricompartmental Total Knee Replacement JAMA. ,vol. 271, pp. 1349- 1357 ,(1994) , 10.1001/JAMA.1994.03510410061034
Prem P. Gogia, James H. Braatz, Steven J. Rose, Barbara J. Norton, Reliability and Validity of Goniometric Measurements at the Knee Physical Therapy. ,vol. 67, pp. 192- 195 ,(1987) , 10.1093/PTJ/67.2.192
Michael A Watkins, Dan L Riddle, Robert L Lamb, Walter J Personius, Reliability of Goniometric Measurements and Visual Estimates of Knee Range of Motion Obtained in a Clinical Setting Physical Therapy. ,vol. 71, pp. 90- 96 ,(1991) , 10.1093/PTJ/71.2.90
Jules M. Rothstein, Peter J. Miller, Richard F. Roettger, Goniometric Reliability in a Clinical Setting Physical Therapy. ,vol. 63, pp. 1611- 1615 ,(1983) , 10.1093/PTJ/63.10.1611
Donna C. Boone, Stanley P. Azen, Chun-Mei Lin, Carol Spence, Carol Baron, Lynn Lee, Reliability of Goniometric Measurements Physical Therapy. ,vol. 58, pp. 1355- 1360 ,(1978) , 10.1093/PTJ/58.11.1355