The measurement of the flammability limits of mists

作者: S.J. Cook , C.F. Cullis , A.J. Good

DOI: 10.1016/0010-2180(77)90079-7

关键词:

摘要: … For OM 100 oil, measurements of lower flammability limits were confined to large droplet sizes, due to the high viscosity, which caused a low rate of flow of oil in the hypodermic needles …

参考文章(5)
Yukio Mizutani, Mitsunobu Ogasawara, Laminar flame propagation in droplet suspension of liquid fuel International Journal of Heat and Mass Transfer. ,vol. 8, pp. 921- 935 ,(1965) , 10.1016/0017-9310(65)90076-1
K R May, The Measurement of Airborne Droplets by the Magnesium Oxide Method Journal of Scientific Instruments. ,vol. 27, pp. 128- 130 ,(1950) , 10.1088/0950-7671/27/5/304
W R Lane, A Microburette for Producing Small Liquid Drops of Known Size Journal of Scientific Instruments. ,vol. 24, pp. 98- 101 ,(1947) , 10.1088/0950-7671/24/4/307
L.A. Lovachev, V.S. Babkin, V.A. Bunev, A.V. V'Yun, V.N. Krivulin, A.N. Baratov, Flammability limits: an invited review Combustion and Flame. ,vol. 20, pp. 259- 289 ,(1973) , 10.1016/S0010-2180(73)80180-4
Alan Williams, Combustion of droplets of liquid fuels: A review Combustion and Flame. ,vol. 21, pp. 1- 31 ,(1973) , 10.1016/0010-2180(73)90002-3