A method for correctly setting the rf flip angle.

作者: William H. Perman , Matt A. Bernstein , John C. Sandstrom

DOI: 10.1002/MRM.1910090104

关键词:

摘要: Currently the accepted method for setting correct rf power levels to achieve 90° and 180° pulses MR imaging is peak echo amplitude of a spin-echo sequence. The this α-2α pulse sequence proportional sin3(α) has relatively broad maximum. Recently another flip angle by maximizing ratio stimulated primary amplitudes (in 3α sequence) demonstrated accuracy similar that using shorter repetition time. We present new, more sensitive, accurate pulses. In method, based upon sequence, we are able accurately set within ±0.1 dB minimizing signal third spin echo. This null works both selective nonselective or 180°, allowing user adjust relative four types single © 1989 Academic Press, Inc.

参考文章(18)
Eiichi Fukushima, Stephen B.W. Roeder, Experimental pulse NMR : a nuts and bolts approach CRC Press. ,(2018) , 10.1201/9780429493867
W.H. Perman, S.K. Hilal, H.E. Simon, A.A. Maudsley, Contrast manipulation in NMR imaging Magnetic Resonance Imaging. ,vol. 2, pp. 23- 32 ,(1984) , 10.1016/0730-725X(84)90121-8
David S. Martin, Freeman and Johnson's Clinical Radionuclide Imaging. 3d ed. 2 vols Radiology. ,vol. 157, pp. 238- 238 ,(1985) , 10.1148/RADIOLOGY.157.1.238
William Sattin, Thomas H Mareci, Katherine N Scott, Exploiting the stimulated echo in nuclear magnetic resonance imaging. II. Applications Journal of Magnetic Resonance. ,vol. 65, pp. 298- 307 ,(1985) , 10.1016/0022-2364(85)90010-1
P Mansfield, A A Maudsley, T Bains, Fast scan proton density imaging by NMR Journal of Physics E: Scientific Instruments. ,vol. 9, pp. 271- 278 ,(1976) , 10.1088/0022-3735/9/4/011
D.G Hughes, Errors in T2 values measured with the Carr-Purcell-Meiboom-Gill pulsed NMR sequence Journal of Magnetic Resonance (1969). ,vol. 26, pp. 481- 489 ,(1977) , 10.1016/0022-2364(77)90099-3
J Frahm, K.D Merboldt, W Hänicke, A Haase, Stimulated echo imaging Journal of Magnetic Resonance. ,vol. 64, pp. 81- 93 ,(1985) , 10.1016/0022-2364(85)90033-2
I L Pykett, B R Rosen, F S Buonanno, T J Brady, Measurement of spin-lattice relaxation times in nuclear magnetic resonance imaging Physics in Medicine and Biology. ,vol. 28, pp. 723- 729 ,(1983) , 10.1088/0031-9155/28/6/012
J. E. Tanner, Use of the Stimulated Echo in NMR Diffusion Studies The Journal of Chemical Physics. ,vol. 52, pp. 2523- 2526 ,(1970) , 10.1063/1.1673336
M. O'Donnell, W.J. Adams, Selective time-reversal pulses for NMR imaging. Magnetic Resonance Imaging. ,vol. 3, pp. 377- 382 ,(1985) , 10.1016/0730-725X(85)90401-1