Non-contact Pulse Wave Velocity Assessment Using Optical Methods

作者: T. Pereira , M. Cabeleira , P. Matos , E. Borges , V. Almeida

DOI: 10.1007/978-3-642-29752-6_18

关键词:

摘要: The clinical relevance of pulse wave velocity (PWV), as an indicator cardiac risk associated to arterial stiffness, has gained over the last years. Optic sensors are attractive instrumental solution for this type measurement due their truly non-contact operation capability, which potential interference free measurement. nature optically originated signals, however, poses new challenges designer, either at probe design level signal processing required extract timing information that yields PWV. In work we describe construction two prototype optical probes and discuss evaluation using three algorithms transit time (PTT) evaluation. Results, obtained in a dedicated test bench, is also described, demonstrate possibility measuring times short 1ms with less than 1% error.

参考文章(8)
Minnan Xu, Local measurement of the pulse wave velocity using Doppler ultrasound Massachusetts Institute of Technology. ,(2002)
S J Vermeersch, E R Rietzschel, M L De Buyzere, D De Bacquer, G De Backer, L M Van Bortel, T C Gillebert, P R Verdonck, P Segers, Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects. Physiological Measurement. ,vol. 29, pp. 1267- 1280 ,(2008) , 10.1088/0967-3334/29/11/003
Jan Kips, Floris Vanmolkot, Dries Mahieu, Sebastian Vermeersch, Isabelle Fabry, Jan de Hoon, Luc Van Bortel, Patrick Segers, The use of diameter distension waveforms as an alternative for tonometric pressure to assess carotid blood pressure Physiological Measurement. ,vol. 31, pp. 543- 553 ,(2010) , 10.1088/0967-3334/31/4/006
The Velocity of the Pulse Wave in Man Proceedings of The Royal Society B: Biological Sciences. ,vol. 93, pp. 298- 306 ,(1922) , 10.1098/RSPB.1922.0022
Marek W Rajzer, Wiktoria Wojciechowska, Marek Klocek, Ilona Palka, Małgorzata Brzozowska-Kiszka, Kalina Kawecka-Jaszcz, Comparison of aortic pulse wave velocity measured by three techniques: Complior, Sphygmocor and Arteriograph Journal of Hypertension. ,vol. 26, pp. 2001- 2007 ,(2008) , 10.1097/HJH.0B013E32830A4A25
M. Azaria, D. Hertz, Time delay estimation by generalized cross correlation methods IEEE Transactions on Acoustics, Speech, and Signal Processing. ,vol. 32, pp. 280- 285 ,(1984) , 10.1109/TASSP.1984.1164314
S. Laurent, J. Cockcroft, L. Van Bortel, P. Boutouyrie, C. Giannattasio, D. Hayoz, B. Pannier, C. Vlachopoulos, I. Wilkinson, H. Struijker-Boudier, , Expert consensus document on arterial stiffness: methodological issues and clinical applications European Heart Journal. ,vol. 27, pp. 2588- 2605 ,(2006) , 10.1093/EURHEARTJ/EHL254
Egidijus Kazanavicius, Rolandas Gircys, Arūnas Vrubliauskas, Slava Lugin, MATHEMATICAL METHODS FOR DETERMINING THE FOOT POINT OF THE ARTERIAL PULSE WAVE AND EVALUATION OF PROPOSED METHODS Information Technology and Control. ,vol. 34, ,(2015) , 10.5755/J01.ITC.34.1.11968