Using IBM SPSS statistics to identify predictors of electricity consumption in a UK supermarket

作者: M. Braun , H. Altan , S. Beck

DOI: 10.2495/ESUS130101

关键词:

摘要: In order to save energy in supermarkets, technical solutions need be supported by appropriate maintenance and operation tools. These tools should provide sufficient information detect unusual levels of consumption. Therefore this paper presents an explorative study on a well sub-metered grocery supermarket the UK Yorkshire Humber region. The data collected for included electricity consumption, footfall data, inside outside climate as settings all relevant building timers. Thereafter meaningfulness these predictors was evaluated with ‘stepwise’ option linear regression section SPSS. results generally show very good fit between mathematical model measured (r > 0.95). only exception refrigeration five days. Upon further investigation it found that current reading one days unusually low (proving effectiveness method abnormalities). Based can argued possible use routinely gathered supermarkets or otherwise easily obtained greater abnormalities thus keep consumption minimum.

参考文章(9)
M. G. Rasul, M. Hansen, Performance assessment and improvement of an existing air conditioning system of a supermarket: a case study on bi-lo supermarket international conference on energy environment. pp. 55- 60 ,(2008)
David Grayson, Embedding corporate responsibility and sustainability: Marks & Spencer Journal of Management Development. ,vol. 30, pp. 1017- 1026 ,(2011) , 10.1108/02621711111182510
William Chung, Y.V. Hui, Y. Miu Lam, Benchmarking the energy efficiency of commercial buildings Applied Energy. ,vol. 83, pp. 1- 14 ,(2006) , 10.1016/J.APENERGY.2004.11.003
Francis W.H. Yik, W.L. Lee, C.K. Ng, Building energy efficiency and the remuneration of operation and maintenance personnel Facilities. ,vol. 20, pp. 406- 413 ,(2002) , 10.1108/02632770210454331
S.A. Tassou, Y. Ge, A. Hadawey, D. Marriott, Energy consumption and conservation in food retailing Applied Thermal Engineering. ,vol. 31, pp. 147- 156 ,(2011) , 10.1016/J.APPLTHERMALENG.2010.08.023
Buang Alias, Weng Wai Choong, Abdul Hakim Mohammed, Energy awareness development process model Faculty of the Built Environment, University of Malaya, Kuala Lumpur, Malaysia.. ,(2005)
Elizabeth A. Peck, Douglas C. Montgomery, Introduction to Linear Regression Analysis ,(1981)
C Ters, J M Rhiemeier, J Harnisch, Comparative assessment of the climate relevance of supermarket refrigeration systems and equipment. Umweltbundesamt fur Mensch und Umwelt. ,(2009)