FMRI using balanced steady-state free precession (SSFP)

作者: Karla L. Miller

DOI: 10.1016/J.NEUROIMAGE.2011.10.040

关键词:

摘要: Steady-state free precession (SSFP) is a highly-efficient MRI pulse sequence that has been fairly recent arrival in the functional realm. Several methods for using balanced SSFP to detect BOLD signal have proposed date and will be discussed this review. After brief introduction general properties of SSFP, review describes quite different approaches transition-band pass-band terms contrast mechanism. It then discusses potential advantages these techniques, followed by their challenges shortcomings. Finally, it gives an overview some applications considered author's perspective on where techniques are headed. In spirit special issue, author also includes personal history underlying her own explorations area.

参考文章(28)
H. Y. Carr, STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE Physical Review. ,vol. 112, pp. 1693- 1701 ,(1958) , 10.1103/PHYSREV.112.1693
Kai Zhong, Jochen Leupold, Juergen Hennig, Oliver Speck, Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla. Magnetic Resonance in Medicine. ,vol. 57, pp. 67- 73 ,(2007) , 10.1002/MRM.21103
Ming-Long Wu, Pei-Hsin Wu, Teng-Yi Huang, Yi-Yu Shih, Ming-Chung Chou, Hua-Shan Liu, Hsiao-Wen Chung, Cheng-Yu Chen, Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T. Magnetic Resonance in Medicine. ,vol. 57, pp. 369- 379 ,(2007) , 10.1002/MRM.21138
Karla L Miller, Rob HN Tijssen, Nikola Stikov, Thomas W Okell, Steady-state MRI: methods for neuroimaging Imaging in Medicine. ,vol. 3, pp. 93- 105 ,(2011) , 10.2217/IIM.10.66
Klaus Scheffler, Erich Seifritz, Deniz Bilecen, Ramesh Venkatesan, J�rgen Hennig, Michael Deimling, E. Mark Haacke, Detection of BOLD changes by means of a frequency-sensitive trueFISP technique: preliminary results NMR in Biomedicine. ,vol. 14, pp. 490- 496 ,(2001) , 10.1002/NBM.726
Rob H.N. Tijssen, Thomas W. Okell, Karla L. Miller, Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI NeuroImage. ,vol. 57, pp. 1364- 1375 ,(2011) , 10.1016/J.NEUROIMAGE.2011.05.070
Rohan Dharmakumar, Xiuling Qi, Juimiin Hong, Graham A. Wright, Detecting microcirculatory changes in blood oxygen state with steady-state free precession imaging. Magnetic Resonance in Medicine. ,vol. 55, pp. 1372- 1380 ,(2006) , 10.1002/MRM.20911
Klaus Scheffler, Stefan Lehnhardt, Principles and applications of balanced SSFP techniques European Radiology. ,vol. 13, pp. 2409- 2418 ,(2003) , 10.1007/S00330-003-1957-X
Yuval Zur, Saul Stokar, Peter Bendel, An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magnetic Resonance in Medicine. ,vol. 6, pp. 175- 193 ,(1988) , 10.1002/MRM.1910060206