Fast and simultaneous determination of endocrine disrupting compounds by ultra-high performance liquid chromatography–tandem mass spectrometry

作者: C. Esteve , L. Herrero , B. Gómara , J.E. Quintanilla-López

DOI: 10.1016/J.TALANTA.2015.08.064

关键词:

摘要: A rapid and sensitive analytical method for the simultaneous determination of thirteen endocrine disruptors (five phthalates, seven parabens, bisphenol A) in a single chromatographic run has been developed first time. The separation method, based on ultra-high performance liquid chromatography (UHPLC), allows all compounds (including isobaric pairs) less than 4.1 min. fast polarity switching mode triple quadrupole mass spectrometer used enables registration positive (phthalates) negative (parabens BPA) ions same acquisition run. Response Surface Methodology was optimization method. optimum elution program starts with 0.2 min isocratic conditions (79.8% water; 20% acetonitrile, 0.2% ammonium formate 5mM at pH 10.2), then content acetonitrile is linearly increased 2 up to 42%, later 98% 1.1 characteristics were satisfactory. robust showed linear response coefficients (R(2)) higher 0.991 range 5.0-2000 pg column (or higher) investigated. Instrumental intra- inter-day precision (expressed as relative standard deviation) lower 12% parabens A, between 5.9% 27% phthalates. detection quantification limits (iLODs iLOQs) medium-high femtograms (270-1300 iLODs). Finally, suitability demonstrated through its application analysis commercial personal care products (shower gels) without any sample treatment, only simple dilution, being possible determine presence almost gels analyzed.

参考文章(41)
George Derringer, Ronald Suich, Simultaneous Optimization of Several Response Variables Journal of Quality Technology. ,vol. 12, pp. 214- 219 ,(1980) , 10.1080/00224065.1980.11980968
M. López-Nogueroles, J. L. Benedé, A. Chisvert, A. Salvador, A rapid and sensitive gas chromatography-mass spectrometry method for the quality control of perfumes: simultaneous determination of phthalates Analytical Methods. ,vol. 5, pp. 409- 415 ,(2013) , 10.1039/C2AY26130H
Gerardo Alvarez-Rivera, Marlene Vila, Marta Lores, Carmen Garcia-Jares, Maria Llompart, Development of a multi-preservative method based on solid-phase microextraction-gas chromatography-tandem mass spectrometry for cosmetic analysis. Journal of Chromatography A. ,vol. 1339, pp. 13- 25 ,(2014) , 10.1016/J.CHROMA.2014.02.075
R. Cela, E.Y. Ordoñez, J.B. Quintana, R. Rodil, Chemometric-assisted method development in reversed-phase liquid chromatography Journal of Chromatography A. ,vol. 1287, pp. 2- 22 ,(2013) , 10.1016/J.CHROMA.2012.07.081
Rong Zhu, Wenhui Zhao, Meijuan Zhai, Fangdi Wei, Zheng Cai, Na Sheng, Qin Hu, Molecularly imprinted layer-coated silica nanoparticles for selective solid-phase extraction of bisphenol A from chemical cleansing and cosmetics samples Analytica Chimica Acta. ,vol. 658, pp. 209- 216 ,(2010) , 10.1016/J.ACA.2009.11.008
Lucia Sanchez-Prado, Maria Llompart, J. Pablo Lamas, Carmen Garcia-Jares, Marta Lores, Multicomponent analytical methodology to control phthalates, synthetic musks, fragrance allergens and preservatives in perfumes Talanta. ,vol. 85, pp. 370- 379 ,(2011) , 10.1016/J.TALANTA.2011.03.079