作者: Qingxiang Zhou , Xiaoguo Zhang , Guohong Xie , Junping Xiao
关键词:
摘要: This article describes a new, rapid and sensitive method for the determination of chlorotoluron, diethofencarb chlorbenzuron from water samples with temperature-controlled ionic liquid-dispersive liquid-phase microextraction. In preconcentration procedure, liquid 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM] [PF(6)] was employed as extraction solvent. The parameters, such volume [PF(6)], sample pH, time, centrifuging temperature salting-out effect, were investigated in detail. Under optimal conditions, it has been found that three analytes had excellent LODs (S/N=3) range 0.04-0.43 microg/L. RSDs (n=6) 1.3-4.7%. proposed evaluated lake water, tap melted snow samples. experimental results indicated prospect would be widely used future.