In vivo EPR tooth dosimetry for triage after a radiation event involving large populations.

作者: Benjamin B. Williams , Ann Barry Flood , Ildar Salikhov , Kyo Kobayashi , Ruhong Dong

DOI: 10.1007/S00411-014-0534-9

关键词:

摘要: The management of radiation injuries following a catastrophic event where large numbers people may have been exposed to life-threatening doses ionizing will rely critically on the availability and use suitable biodosimetry methods. In vivo electron paramagnetic resonance (EPR) tooth dosimetry has number valuable unique characteristics capabilities that help enable effective triage. We produced prototype deployable EPR dosimeter tested it in several vitro studies characterize performance utility at state art. This report focuses recent advances technology, which strengthen evidence can provide practical, accurate, rapid measurements context its intended triage victims an improvised nuclear device. These signal is stable, accurate within 0.5 Gy, be successfully carried out vivo. stability over time radiation-induced from whole teeth was measured confirm long-term better behavior hours irradiation. Dosimetry were taken for five pairs natural human upper central incisors mounted simple anatomic mouth model demonstrates ability achieve Gy standard error inverse dose prediction. An assessment intact estimation screening performed with volunteer subjects who not significant levels patients undergone total body irradiation as part bone marrow transplant procedures. Based these previous evaluations system, concluded this system could very resource aid massive radiological event.

参考文章(25)
N NAKAMURA, C. MIYAZAWA, S SAWADA, M AKIYAMA, A.A AWA, A close correlation between electron spin resonance (ESR) dosimetry from tooth enamel and cytogenetic dosimetry from lymphocytes of Hiroshima atomic-bomb survivors. International Journal of Radiation Biology. ,vol. 73, pp. 619- 627 ,(1998) , 10.1080/095530098141870
Akinori Iwasaki, Tadeusz Walczak, Oleg Grinberg, Harold M. Swartz, Differentiation of the observed low frequency (1200 MHz) EPR signals in whole human teeth Applied Radiation and Isotopes. ,vol. 62, pp. 133- 139 ,(2005) , 10.1016/J.APRADISO.2004.08.038
Marcy B. Grace, Brian R. Moyer, Joanna Prasher, Kenneth D. Cliffer, Narayani Ramakrishnan, Joseph Kaminski, C Norman Coleman, Ronald G. Manning, Bert W. Maidment, Richard Hatchett, Rapid radiation dose assessment for radiological public health emergencies: roles of NIAID and BARDA. Health Physics. ,vol. 98, pp. 172- 178 ,(2010) , 10.1097/01.HP.0000348001.60905.C0
Harold M. Swartz, Ann Barry Flood, Robert M. Gougelet, Michael E. Rea, Roberto J. Nicolalde, Benjamin B. Williams, A critical assessment of biodosimetry methods for large-scale incidents. Health Physics. ,vol. 98, pp. 95- 108 ,(2010) , 10.1097/HP.0B013E3181B8CFFD
I. Salikhov, T. Walczak, P. Lesniewski, N. Khan, A. Iwasaki, R. Comi, J. Buckey, H. M. Swartz, EPR spectrometer for clinical applications. Magnetic Resonance in Medicine. ,vol. 54, pp. 1317- 1320 ,(2005) , 10.1002/MRM.20689
Roberto J. Nicolalde, Robert M. Gougelet, Michael Rea, Benjamin B. Williams, Ruhong Dong, Maciej M. Kmiec, Piotr N. Lesniewski, Harold M. Swartz, THE VIEW FROM THE TRENCHES: PART 2–TECHNICAL CONSIDERATIONS FOR EPR SCREENING Health Physics. ,vol. 98, pp. 128- 135 ,(2010) , 10.1097/01.HP.0000348461.00071.10
Ildar Salikhov, Hiroshi Hirata, Tadeusz Walczak, Harold M. Swartz, An improved external loop resonator for in vivo L-band EPR spectroscopy Journal of Magnetic Resonance. ,vol. 164, pp. 54- 59 ,(2003) , 10.1016/S1090-7807(03)00175-7
George A. Rinard, Richard W. Quine, Sandra S. Eaton, Gareth R. Eaton, Frequency Dependence of EPR Signal Intensity, 248 MHz to 1.4 GHz Journal of Magnetic Resonance. ,vol. 154, pp. 80- 84 ,(2002) , 10.1006/JMRE.2001.2455
T. Walczak, P. Leśniewski, I. Salikhov, A. Sucheta, K. Szybiński, H. M. Swartz, L-band electron paramagnetic resonance spectrometer for use in vivo and in studies of aqueous biological samples Review of Scientific Instruments. ,vol. 76, pp. 013107- ,(2005) , 10.1063/1.1832271