On-line post-column fluorescence derivatization of arginine-containing peptides in high-perfomance liquid chromatography

作者: Masahiro Ohno , Masaaki Kai , Yosuke Ohkura

DOI: 10.1016/S0021-9673(01)94275-X

关键词:

摘要: Abstract A selective detection system based on on-line post-column fluorescence derivatization is described for the analysis of arginine-containing peptides by high-performance liquid chromatography. The are automatically converted into fluorescent derivatives with benzoin, a fluoregenic reagent guarnidino compounds, after separation reversed-phase column (TSK gel ODS-120T) and in an ultraviolet absorption detector. permits at 435 nm emission irradiation 325 as little picomole amounts. chromatogram obtained fluroscence only shows peaks corresponding to peptides. facile fragments tryptic digest β-melanocyte stimulating hormone model compound could be achieved comparison 215 nm.

参考文章(16)
MASAAKI KAI, TETSURO MIURA, KAZUYA KOHASHI, YOSUKE OHKURA, New Method for the Fluorimetric Determination of Guanidino Compounds with Benzoin Chemical & Pharmaceutical Bulletin. ,vol. 29, pp. 1115- 1120 ,(1981) , 10.1248/CPB.29.1115
Michael M. Chang, Susan E. Leeman, Isolation of a sialogogic peptide from bovine hypothalamic tissue and its characterization as substance P Journal of Biological Chemistry. ,vol. 245, pp. 4784- 4790 ,(1970) , 10.1016/S0021-9258(18)62860-1
E.C. Nice, M.J. O'Hare, Simultaneous separation of β-lipotrophin, adrenocorticotropic hormone, endorphins and enkephalins by high-performance liquid chromatography Journal of Chromatography B: Biomedical Sciences and Applications. ,vol. 162, pp. 401- 407 ,(1979) , 10.1016/S0378-4347(00)81527-3
Chao-Yuh Yang, Henry J. Pownall, Antonio M. Gotto, Identification of peptides containing tryptophan, tyrosine, and phenylalanine using photodiode-array spectrophotometry. Analytical Biochemistry. ,vol. 145, pp. 67- 72 ,(1985) , 10.1016/0003-2697(85)90327-6
Peter Böhlen, Stanley Stein, James Stone, Sidney Udenfriend, Automatic monitoring of primary amines in preparative column effluents with fluorescamine Analytical Biochemistry. ,vol. 67, pp. 438- 445 ,(1975) , 10.1016/0003-2697(75)90316-4
E. Saito, W. D. Odell, Corticotropin/lipotropin common precursor-like material in normal rat extrapituitary tissues. Proceedings of the National Academy of Sciences of the United States of America. ,vol. 80, pp. 3792- 3796 ,(1983) , 10.1073/PNAS.80.12.3792
MR Lee, The renin/angiotensin system. British Journal of Clinical Pharmacology. ,vol. 12, pp. 605- 612 ,(1981) , 10.1111/J.1365-2125.1981.TB01278.X
H YANG, J HONG, E COSTA, Regional distribution of LEU and MET enkephalin in rat brain. Neuropharmacology. ,vol. 16, pp. 303- 307 ,(1977) , 10.1016/0028-3908(77)90112-5
Hiroshi Takagi, Hirohito Shiomi, Hiroshi Ueda, Hiro Amano, A novel analgesic dipeptide from bovine brain is a possible Met-enkephalin releaser. Nature. ,vol. 282, pp. 410- 412 ,(1979) , 10.1038/282410A0