Circulatory changes following adrenalectomy in the rat.

作者: F. J. IMMS , R. L. B. NEAME

DOI: 10.1093/CVR/8.2.268

关键词:

摘要: In the rat adrenalectomy decreases cardiac output, stroke volume, and left ventricular work when these are measured one, three, seven days after operation. Arterial blood pressure is normal on first third because of a compensatory increase in total peripheral resistance. On seventh day animals were showing obvious adrenocortical insufficiency there was marked fall pressure. Substitution 0·9% NaC1 solution for drinking water improves function postoperative day. Cardiac all greater than maintained, adrenalectomized approach levels. The normal. These apparently healthy, ate well, growing.

参考文章(22)
Daniel C. Darrow, Harold E. Harrison, Max Taffel, TISSUE ELECTROLYTES IN ADRENAL INSUFFICIENCY Journal of Biological Chemistry. ,vol. 130, pp. 487- 502 ,(1939) , 10.1016/S0021-9258(18)73519-9
William C. Ullrick, Betsy B. Brennan, William V. Whitehorn, Characteristics of cardiac tissue from adrenalectomized rats American Journal of Physiology-Legacy Content. ,vol. 200, pp. 117- 121 ,(1961) , 10.1152/AJPLEGACY.1961.200.1.117
RL Verrier, MJ Rovetto, AM Lefer, Blood volume and myocardial function in adrenal insufficiency. American Journal of Physiology. ,vol. 217, pp. 1559- 1564 ,(1969) , 10.1152/AJPLEGACY.1969.217.6.1559
NEIL SOLOMON, RANDALL H. TRAVIS, GEORGE SAYERS, Corticosteroids and the functional capacity of the rat heart-lung preparation. Endocrinology. ,vol. 64, pp. 535- 541 ,(1959) , 10.1210/ENDO-64-4-535
Morris J. Mandel, Leo A. Sapirstein, Effect of angiotensin infusion on regional blood flow and regional vascular resistance in the rat Circulation Research. ,vol. 10, pp. 807- 816 ,(1962) , 10.1161/01.RES.10.5.807
P.M. Caesar, G.G.S. Collins, M. Sandler, Catecholam1ne metabolism and monoamine oxidase activity tn adrenalectomized rats Biochemical Pharmacology. ,vol. 19, pp. 921- 926 ,(1970) , 10.1016/0006-2952(70)90255-8
A. W. Richardson, T. Cooper, T. Pinakatt, Thermodilution method for measuring cardiac output of rats by using a transistor bridge. Science. ,vol. 135, pp. 317- 318 ,(1962) , 10.1126/SCIENCE.135.3500.317
William S. Spector, Handbook of biological data. Handbook of biological data.. ,(1956)
George Fegler, MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD Quarterly Journal of Experimental Physiology and Cognate Medical Sciences. ,vol. 39, pp. 153- 164 ,(1954) , 10.1113/EXPPHYSIOL.1954.SP001067