作者: P. Pękala
DOI:
关键词:
摘要: The experimental verification of the acoustic field model based on cone-tracing method [1, 2] is described. With simulated echograms and impulse responses obtained experimentally, a set parameters: Early Decay Time (EDT), C50 C80 were obtained. parameters measured at many receiving sites those calculated compared. Mean differences less than 2 dB observed for octave band mid-frequencies above 125 Hz.