Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact.

作者: Stefan Debener , Alexander Strobel , Bettina Sorger , Judith Peters , Cornelia Kranczioch

DOI: 10.1016/J.NEUROIMAGE.2006.09.031

关键词:

摘要: EEG signals recorded simultaneously with fMRI are massively compromised by severe artefacts, among them the cardiac cycle-related ballistocardiogram (BCG) artefact. Different methods have been proposed to remove BCG artefact focusing on channel-wise template subtraction procedures or spatial filtering approaches such as independent component analysis (ICA). Here we systematically compared performance of optimal basis set (OBS), a correction approach, ICA and recently combination both (OBS–ICA). The three different were applied 60-channel data from 12 subjects during acquisition in 3-T scanner. In addition examination residual artefact, signal-to-noise ratio (SNR) topography resulting auditory evoked potential N1 compared. Whereas all led significant reduction, procedure resulted significantly reduced SNR amplitude when BCG-uncorrected data, indicating rather poor performance. contrast ICA, OBS OBS–ICA corrected substantially improved N1. quality was investigated means equivalent current dipole modelling. On descriptive level, localization error data. This improvement for OBS–ICA. We conclude that can efficiently artefacts improve inside scanner, prerequisite successful integration fMRI.

参考文章(40)
Stefan Debener, Markus Ullsperger, Markus Siegel, Andreas K. Engel, Single-trial EEG–fMRI reveals the dynamics of cognitive function Trends in Cognitive Sciences. ,vol. 10, pp. 558- 563 ,(2006) , 10.1016/J.TICS.2006.09.010
Tzyy-Ping Jung, Scott Makeig, Marissa Westerfield, Jeanne Townsend, Eric Courchesne, Terrence J. Sejnowski, Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects Clinical Neurophysiology. ,vol. 111, pp. 1745- 1758 ,(2000) , 10.1016/S1388-2457(00)00386-2
Philip J. Allen, Giovanni Polizzi, Karsten Krakow, David R. Fish, Louis Lemieux, Identification of EEG events in the MR scanner : The problem of pulse artifact and a method for its subtraction NeuroImage. ,vol. 8, pp. 229- 239 ,(1998) , 10.1006/NIMG.1998.0361
J Sijbers, J Van Audekerke, M Verhoye, A Van der Linden, D Van Dyck, Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. Magnetic Resonance Imaging. ,vol. 18, pp. 881- 886 ,(2000) , 10.1016/S0730-725X(00)00178-8
Philip J. Allen, Oliver Josephs, Robert Turner, A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI NeuroImage. ,vol. 12, pp. 230- 239 ,(2000) , 10.1006/NIMG.2000.0599
Julie Onton, Arnaud Delorme, Scott Makeig, None, Frontal midline EEG dynamics during working memory. NeuroImage. ,vol. 27, pp. 341- 356 ,(2005) , 10.1016/J.NEUROIMAGE.2005.04.014
Arnaud Delorme, Scott Makeig, Michèle Fabre-Thorpe, Terrence Sejnowski, None, From single-trial EEG to brain area dynamics Neurocomputing. ,vol. 44, pp. 1057- 1064 ,(2002) , 10.1016/S0925-2312(02)00415-0
André Brechmann, Frank Baumgart, Henning Scheich, Sound-level-dependent representation of frequency modulations in human auditory cortex: a low-noise fMRI study. Journal of Neurophysiology. ,vol. 87, pp. 423- 433 ,(2002) , 10.1152/JN.00187.2001
Tobias Schicke, Lars Muckli, Anton L. Beer, Michael Wibral, Wolf Singer, Rainer Goebel, Frank Rösler, Brigitte Röder, Tight covariation of BOLD signal changes and slow ERPs in the parietal cortex in a parametric spatial imagery task with haptic acquisition. European Journal of Neuroscience. ,vol. 23, pp. 1910- 1918 ,(2006) , 10.1111/J.1460-9568.2006.04720.X
M Scherg, D Von Cramon, Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model. Electroencephalography and Clinical Neurophysiology. ,vol. 62, pp. 32- 44 ,(1985) , 10.1016/0168-5597(85)90033-4