Preconcentration of trace amounts of tungsten on Amberlite XAD-7 for its spectrophotometric determination in hot spring water

作者: M Soylak , L Elci , M Doğan

DOI: 10.1007/BF00321654

关键词:

摘要: A preconcentration procedure, using a short column loaded with Amberlite XAD-7, is proposed for the spectrophotometric determination of traces tungsten. The procedure based on retention tungsten resin after its reduction to W(V)-thiocyanate complex tin(II) chloride solution. Interference effects have been shown be neglible foreign ions including Ca2+, Mg2+, Na+, SO42−, F−, NO3−, Cu2+, Fe3+ and Mo6+. has applied hot spring water satisfactory results (Recovery > 95%; relative standard deviation < 5%; error 3%).

参考文章(20)
I. M. Kolthoff, E. B. Sandell, Textbook of quantitative inorganic analysis ,(1948)