Influence of paramagnetic contrast on single-shot MRCP image quality

作者: S. Takahashi , T. Kim , T. Murakami , A. Okada , M. Hori

DOI: 10.1007/S002610000083

关键词:

摘要: To assess the ability of gadolinium enhancement to suppress overlapping vessel signals that diminish image quality magnetic resonance cholangiopancreatography (MRCP), we obtained MRCP before and after intravenous injection gadolinium. Signal intensity ratio common bile duct main pancreatic was significantly improved contrast media. The postcontrast better than precontrast one.

参考文章(11)
O Ernst, M Calvo, G Sergent, D Mizrahi, F Carpentier, Breath-hold MR cholangiopancreatography using a HASTE sequence: comparison of single-slice and multislice acquisition techniques. American Journal of Roentgenology. ,vol. 169, pp. 1304- 1306 ,(1997) , 10.2214/AJR.169.5.9353446
T Miyazaki, Y Yamashita, T Tsuchigame, H Yamamoto, J Urata, M Takahashi, MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences. American Journal of Roentgenology. ,vol. 166, pp. 1297- 1303 ,(1996) , 10.2214/AJR.166.6.8633435
P. Tervahartiala, L. Kivisaari, A. Lamminen, A. Maschek, H. Wo¨hling, C.-G. Standertskjo¨ld-Nordenstam, Dynamic fast-gradient echo MR imaging of pancreatic tumours European Journal of Radiology. ,vol. 25, pp. 74- 80 ,(1997) , 10.1016/S0720-048X(96)01089-3
J T Ferrucci, Advances in abdominal MR imaging. Radiographics. ,vol. 18, pp. 1569- 1586 ,(1998) , 10.1148/RADIOGRAPHICS.18.6.9821200
K J Murphy, J A Brunberg, R H Cohan, Adverse reactions to gadolinium contrast media: a review of 36 cases. American Journal of Roentgenology. ,vol. 167, pp. 847- 849 ,(1996) , 10.2214/AJR.167.4.8819369
M G Lee, Y K Jeong, M H Kim, S G Lee, E M Kang, D Chien, Y M Shin, H K Ha, P N Kim, Y H Auh, MR cholangiopancreatography of pancreaticobiliary diseases: comparing single-shot RARE and multislice HASTE sequences. American Journal of Roentgenology. ,vol. 171, pp. 1539- 1545 ,(1998) , 10.2214/AJR.171.6.9843285
Y Yamashita, Y Abe, Y Tang, J Urata, S Sumi, M Takahashi, In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. American Journal of Roentgenology. ,vol. 168, pp. 1449- 1454 ,(1997) , 10.2214/AJR.168.6.9168706
Qun Chen, Bettina Siewert, Benjamin Martin Bly, Steven Warach, Robert R. Edelman, STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact Magnetic Resonance in Medicine. ,vol. 38, pp. 404- 408 ,(1997) , 10.1002/MRM.1910380308
T Ichikawa, H Haradome, J Hachiya, T Nitatori, T Araki, Perfusion-weighted MR imaging in the upper abdomen: preliminary clinical experience in 61 patients. American Journal of Roentgenology. ,vol. 169, pp. 1061- 1066 ,(1997) , 10.2214/AJR.169.4.9308465
Noriyuki Moriyama, Takayuki Hayashi, Ryuzou Sekiguchi, Shigeru Nawano, Mituo Satake, Kazuhisa Nemoto, Ryouko Iwata, Kouji Murakami, Staging of pancreatic ductal adenocarcinoma using dynamic MR imaging Nihon Igaku Hōshasen Gakkai zasshi. Nippon acta radiologica. ,vol. 57, pp. 596- 601 ,(1997)