摘要: Abstract A highly integrated, Field Programmable Gate Array (FPGA) based induction measurement system for conductive flow level is presented. Exploiting under-sampling and digital I/Q demodulation techniques, the use direct sampling can operate at multiple frequencies (from 100 kHz to over 10 MHz). Details are discussed in both hardware software aspects. Simulations experiments 2.6 MHz 8.3 MHz carried out using saline solutions with conductivities of 1.8 S/m 4.3 S/m verify performance system. Application monitoring implemented studied, which further proves applicability low conductivity object measurements.

参考文章(35)
Clayton T Crowe, None, Multiphase Flow Handbook CRC Press. ,(2005) , 10.1201/9781420040470
M Soleimani, William RB Lionheart, Claudia H Riedel, Olaf Dossel, Forward problem in 3D magnetic induction tomography (MIT) Proceedings of the 3rd World Congress on Industrial Process Tomography. pp. 275- 280 ,(2003)
M. Zolgharni, P.D. Ledger, D.W. Armitage, D.S. Holder, H. Griffiths, Detection of haemorrhagic cerebral stroke by magnetic induction tomography: FE and TLM numerical modelling In: Electrical Impedance Tomography Conference, Dartmouth College, Hanover, New Hampshire, USA; 2008.. ,(2008)
H. S. Tapp, R. O. Mackin, A. J. Peyton, D. Goss, E. Crescenzo, W. A. Wan-Daud, N. H. Saunders, Addressing the difficulties in using inductive methods to evaluating human body composition. Biom�trie Humaine et Anthropologie. 2003;21:63-71.. ,vol. 21, pp. 69- 77 ,(2003)
Robert Merwa, Karl Hollaus, Oszkar Biró, Hermann Scharfetter, Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability. Physiological Measurement. ,vol. 25, pp. 347- 354 ,(2004) , 10.1088/0967-3334/25/1/038
N Terzija, W Yin, G Gerbeth, F Stefani, K Timmel, T Wondrak, A J Peyton, Use of electromagnetic induction tomography for monitoring liquid metal/gas flow regimes on a model of an industrial steel caster Measurement Science and Technology. ,vol. 22, pp. 015501- ,(2011) , 10.1088/0957-0233/22/1/015501
Hermann Scharfetter, Robert Merwa, Karl Pilz, A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT). Physiological Measurement. ,vol. 26, pp. 307- 318 ,(2005) , 10.1088/0967-3334/26/2/028
R Patz, S Watson, C Ktistis, M Hamsch, A J Peyton, Performance of a FPGA-based Direct Digitising Signal Measurement module for MIT Journal of Physics: Conference Series. ,vol. 224, pp. 012017- ,(2010) , 10.1088/1742-6596/224/1/012017
J Rosell-Ferrer, R Merwa, P Brunner, H Scharfetter, A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration. Physiological Measurement. ,vol. 27, pp. 271- 280 ,(2006) , 10.1088/0967-3334/27/5/S23