Improvement of FBG peak wavelength demodulation using digital signal processing algorithms

作者: Damian Harasim , Yussupova Gulbahar

DOI: 10.1117/12.2205547

关键词:

摘要: … extending force applied to measured sample, FBG sensor … To receive reference characteristics with high signal to noise ratio … With the same applied forces, we traced spectra with sensor …

参考文章(21)
Thomas Bodendorfer, Mathias S. Muller, Florian Hirth, Alexander W. Koch, Comparison of different peak detection algorithms with regards to spectrometic fiber Bragg grating interrogation systems international symposium on optomechatronic technologies. pp. 122- 126 ,(2009) , 10.1109/ISOT.2009.5326110
J.M. Gong, C.C. Chan, W. Jin, J.M.K. MacAlpine, M. Zhang, Y.B. Liao, Enhancement of wavelength detection accuracy in fiber Bragg grating sensors by using a spectrum correlation technique Optics Communications. ,vol. 212, pp. 29- 33 ,(2002) , 10.1016/S0030-4018(02)01907-7
Gayan C. Kahandawa, Jayantha Epaarachchi, Hao Wang, John Canning, K.T. Lau, Extraction and processing of real time strain of embedded FBG sensors using a fixed filter FBG circuit and an artificial neural network Measurement. ,vol. 46, pp. 4045- 4051 ,(2013) , 10.1016/J.MEASUREMENT.2013.07.029
CC Chan, JM Gong, CZ Shi, Wei Jin, M Zhang, Li Min Zhou, MS Demokan, Improving measurement accuracy of fiber Bragg grating sensor using digital matched filter Sensors and Actuators A-physical. ,vol. 104, pp. 19- 24 ,(2003) , 10.1016/S0924-4247(02)00437-5
Gustavo Rafael Collere Possetti, Ricardo Canute Kamikawachi, Marcia Muller, José Luís Fabris, Metrological Evaluation of Optical Fiber Grating-Based Sensors: An Approach Towards the Standardization Journal of Lightwave Technology. ,vol. 30, pp. 1042- 1052 ,(2012) , 10.1109/JLT.2011.2167500
C.R. Mittermayr, S.G. Nikolov, H. Hutter, M. Grasserbauer, Wavelet denoising of Gaussian peaks: A comparative study Chemometrics and Intelligent Laboratory Systems. ,vol. 34, pp. 187- 202 ,(1996) , 10.1016/0169-7439(96)00026-3
Mousumi Majumder, Tarun Kumar Gangopadhyay, Ashim Kumar Chakraborty, Kamal Dasgupta, D.K. Bhattacharya, Fibre Bragg gratings in structural health monitoring—Present status and applications Sensors and Actuators A-physical. ,vol. 147, pp. 150- 164 ,(2008) , 10.1016/J.SNA.2008.04.008
S. Cięszczyk, Influence of temperature on synthetic data-based calibration models for low resolution open-path FTIR spectroscopy Bulletin of The Polish Academy of Sciences-technical Sciences. ,vol. 62, pp. 33- 42 ,(2014) , 10.2478/BPASTS-2014-0004