Assay-Specific Differences in Lipemic Interference in Native and Intralipid-Supplemented Samples

作者: Joshua A Bornhorst , Richard F Roberts , William L Roberts

DOI: 10.1373/CLINCHEM.2004.040154

关键词:

摘要: … Manufacturers often provide guidelines for the maximum acceptable lipemia that have been established by interference experiments using Intralipid-… by supplementation with Intralipid. …

参考文章(13)
Cooper Gr, Sampson Ej, Magid E, Smith Sj, Myers Gl, Biological variability in the concentration of serum lipids: sources, meta-analysis, estimation, and minimization by relative range measurements. Journal of the International Federation of Clinical Chemistry / IFCC. ,vol. 7, pp. 23- ,(1995)
J R Pearson, R Wells, A Wells, Serum index identifies lipemic samples causing interference with bilirubin assay on Hitachi 717. Clinical Chemistry. ,vol. 37, pp. 2014- 2015 ,(1991) , 10.1093/CLINCHEM/37.11.2014
Edwin V. Pozharski, Leon McWilliams, Robert C. MacDonald, Relationship between Turbidity of Lipid Vesicle Suspensions and Particle Size Analytical Biochemistry. ,vol. 291, pp. 158- 162 ,(2001) , 10.1006/ABIO.2001.5012
Jacqueline Férézou, Annie Gulik, Nicole Domingo, Fabien Milliat, Jean-Claude Dedieu, Suzanne Dunel-Erb, Claudine Chevalier, Andre C. Bach, Intralipid 10%: physicochemical characterization. Nutrition. ,vol. 17, pp. 930- 933 ,(2001) , 10.1016/S0899-9007(01)00667-0
D. Grafmeyer, M. Bondon, M. Manchon, P. Levillain, The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study. Clinical Chemistry and Laboratory Medicine. ,vol. 33, pp. 31- 52 ,(1995) , 10.1515/CCLM.1995.33.1.31
J. T. Whicher, C. P. Price, K. Spencer, A. Milford Ward, Immunonephelometric and Immunoturbidimetric Assays for Proteins Critical Reviews in Clinical Laboratory Sciences. ,vol. 18, pp. 213- 260 ,(1982) , 10.3109/10408368209085072
Christie M Ballantyne, Ron C Hoogeveen, Role of lipid and lipoprotein profiles in risk assessment and therapy. American Heart Journal. ,vol. 146, pp. 227- 233 ,(2003) , 10.1016/S0002-8703(02)94701-0
PJ Twomey, AC Don-Wauchope, D McCullough, Unreliability of triglyceride measurement to predict turbidity induced interference Journal of Clinical Pathology. ,vol. 56, pp. 861- 862 ,(2003) , 10.1136/JCP.56.11.861
M R Glick, K W Ryder, S A Jackson, Graphical comparisons of interferences in clinical chemistry instrumentation. Clinical Chemistry. ,vol. 32, pp. 470- 475 ,(1986) , 10.1093/CLINCHEM/32.3.470