Validation of GEANT3 simulation studies with a dual-head PMT ClearPET/spl trade/ prototype

作者: K. Ziemons , U. Heinrichs , M. Streun , U. Pietrzyk

DOI: 10.1109/NSSMIC.2003.1352542

关键词:

摘要: The ClearPET/spl trade/ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and spatial resolution foreseen for camera using phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) oxyorthosilicate (LSO) scintillating crystals. Design optimizations first photomultiplier tube (PMT) based ClearPET are done with Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built test frontend electronics was used validate implementation tool. Multiple simulations were performed following experimental protocols measure intrinsic profile in axial radial direction. Including mean energy about 27.0% simulated (1.41/spl plusmn/0.11)mm compared measured (1.48/spl plusmn/0.06)mm. profiles show square deviation 12.6% direction 3.6% Satisfactorily these results representative all designs confirm scanner geometry.

参考文章(7)
S.R. Cherry, Y. Shao, R.W. Silverman, K. Meadors, S. Siegel, A. Chatziioannou, J.W. Young, W. Jones, J.C. Moyers, D. Newport, A. Boutefnouchet, T.H. Farquhar, M. Andreaco, M.J. Paulus, D.M. Binkley, R. Nutt, M.E. Phelps, MicroPET: a high resolution PET scanner for imaging small animals ieee nuclear science symposium. ,vol. 44, pp. 1161- 1166 ,(1996) , 10.1109/23.596981
W G Cross, H Ing, N Freedman, A short atlas of beta-ray spectra Physics in Medicine and Biology. ,vol. 28, pp. 1251- 1260 ,(1983) , 10.1088/0031-9155/28/11/005
Yuan-Chuan Tai, Arion F Chatziioannou, Yongfeng Yang, Robert W Silverman, Ken Meadors, Stefan Siegel, Danny F Newport, Jennifer R Stickel, Simon R Cherry, MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging Physics in Medicine and Biology. ,vol. 48, pp. 1519- 1537 ,(2003) , 10.1088/0031-9155/48/11/303
M. Streun, G. Brandenburg, H. Larue, H. Saleh, E. Zimmermann, K. Ziemons, H. Halling, Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET ieee nuclear science symposium. ,vol. 50, pp. 344- 347 ,(2002) , 10.1109/TNS.2003.812449
U. Heinrichs, U. Pietrzyk, K. Ziemons, Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 ieee nuclear science symposium. ,vol. 50, pp. 1428- 1432 ,(2002) , 10.1109/TNS.2003.817409
C.L. Melcher, J.S. Schweitzer, Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator nuclear science symposium and medical imaging conference. ,vol. 39, pp. 502- 505 ,(1991) , 10.1109/23.159655
Y C Tai, A Chatziioannou, S Siegel, J Young, D Newport, R N Goble, R E Nutt, S R Cherry, Performance evaluation of the microPET P4: a PET system dedicated to animal imaging. Physics in Medicine and Biology. ,vol. 46, pp. 1845- 1862 ,(2001) , 10.1088/0031-9155/46/7/308