作者: Fatemeh Dalir , Majid Shafiepour Motlagh , Khosro Ashrafi
DOI: 10.1080/15435075.2017.1279618
关键词:
摘要: ABSTRACTThe present research introduces a well to wire pseudo comprehensive carbon footprint model for combined cycle power plants. The mentioned integrates land use change model, operational and transmission distribution into one model. parameters which their effects are considered in the integrated are: fuel type, emission extraction processing, own consumption of plant, degradation, site ambient condition, losses. For quantifying effectiveness each parameter, sensitivity analyses based on different life scenarios performed. result shows that effect is negligible. electrical energy produced plant until it delivered end users varies from 321 522 g CO2 eq/kWh.