Capacitance-type blade-tip clearance measurement system using a dual amplifier with ramp/DC inputs and integration

作者: G.R. Sarma , J.P. Barranger

DOI: 10.1109/19.177341

关键词:

摘要: … blade tip and mounted capacitance electrode within a guard ring … , it is shown that (1) with a ramp input the circuit has an output … The technique accommodates long cable lengths and …

参考文章(8)
Subrata Kumar Das, ANALYSIS OF TIME-VARYING NETWORKS The University of Arizona.. ,(1966)
Rosario N. Demers, Compressor blade clearance measurement using capacitance and phase lock techniques In AGARD Advanced Instrumentation for Aero Engine Components 10 p (SEE N87-21170 14-31. ,(1986)
M. J. Scotto, M. E. Eismeier, High-Speed Noncontacting Instrumentation for Jet Engine Testing Journal of Engineering for Power. ,vol. 102, pp. 912- 917 ,(1980) , 10.1115/1.3230360
Albert Lazzarini, Sources of error in dynamic applications of electronic displacement sensors Review of Scientific Instruments. ,vol. 57, pp. 3099- 3106 ,(1986) , 10.1063/1.1138997
J. Macdonald, D. Edmondson, Exact Solution of a Time-Varying Capacitance Problem Proceedings of the IRE. ,vol. 49, pp. 453- 466 ,(1961) , 10.1109/JRPROC.1961.287806
J.-C. Lin, J.H. Nevin, A modified time-domain model for nonlinear analysis of an operational amplifier IEEE Journal of Solid-state Circuits. ,vol. 21, pp. 478- 483 ,(1986) , 10.1109/JSSC.1986.1052554
C.T. Chuang, Analysis of the settling behavior of an operational amplifier IEEE Journal of Solid-state Circuits. ,vol. 17, pp. 74- 80 ,(1982) , 10.1109/JSSC.1982.1051689
Garimella R. Sarma, John P. Barranger, Ramp-integration technique for capacitance-type blade-tip clearance measurement Rundbrief Der Gi-fachgruppe 5.10 Informationssystem-architekturen. pp. 591- 600 ,(1986)