Manual control of patient table for bolus-chasing CT angiography

作者: Erwei Bai , Henri Bai , Ge Wang , Kai Zeng

DOI:

关键词:

摘要: In order to reduce contrast dose and radiation exposure involved in CT angiography, an automatic adaptive control scheme was proposed for bolus chasing, which offers substantial improvements over the conventional constant speed scheme. this paper, a manual is utilize expert's knowledge optimally based on real-time imaging feedback. The technical objective synchronize dynamics aperture. To test technique, realistic simulator designed, developed evaluated. It shown statistically that outperforms traditional control.

参考文章(9)
John Halloran, Melhem J. Sharafuddin, Henri Bai, Michael Vannier, Ge Wang, James R. Bennett, Robert McCabe, Ying Liu, Er-Wei Bai, Chenglin Wang, Study of an adaptive bolus chasing CT angiography. Journal of X-ray Science and Technology. ,vol. 14, pp. 27- 38 ,(2006)
Kimberlee Gauvreau, Marcello Pagano, Principles of biostatistics ,(1992)
Zhijun Cai, Robert McCabe, Ge Wang, Er Wei Bai, Bolus chasing computed tomography angiography using local maximum tracking method International Journal of Modelling, Identification and Control. ,vol. 2, pp. 305- 312 ,(2007) , 10.1504/IJMIC.2007.016413
H.-P. Dinkel, M. Fieger, J. Knüpffer, R. Moll, G. Schindler, Optimizing liver contrast in helical liver CT: value of a real-time bolus-triggering technique. European Radiology. ,vol. 8, pp. 1608- 1612 ,(1998) , 10.1007/S003300050596
G D Schweiger, P J Chang, B P Brown, Optimizing contrast enhancement during helical CT of the liver: a comparison of two bolus tracking techniques. American Journal of Roentgenology. ,vol. 171, pp. 1551- 1558 ,(1998) , 10.2214/AJR.171.6.9843287
P M Silverman, S C Roberts, I Ducic, M C Tefft, M C Olson, C Cooper, R K Zeman, Assessment of a technology that permits individualized scan delays on helical hepatic CT: a technique to improve efficiency in use of contrast material. American Journal of Roentgenology. ,vol. 167, pp. 79- 84 ,(1996) , 10.2214/AJR.167.1.8659426
John I. Halloran, Er-Wei Bai, Ge Wang, James R. Bennett, A preliminary study on adaptive field-of-view tracking in peripheral digital subtraction angiography. Journal of X-ray Science and Technology. ,vol. 11, pp. 149- 159 ,(2003)
L Kopka, J Rodenwaldt, U Fischer, D W Mueller, J W Oestmann, E Grabbe, Dual-phase helical CT of the liver: effects of bolus tracking and different volumes of contrast material. Radiology. ,vol. 201, pp. 321- 326 ,(1996) , 10.1148/RADIOLOGY.201.2.8888218
Er-Wei Bai, Zhijun Cai, Robert McCabe, Ge Wang, An Adaptive Optimal Control Design for a Bolus Chasing Computed Tomography Angiography IEEE Transactions on Control Systems and Technology. ,vol. 16, pp. 60- 69 ,(2008) , 10.1109/TCST.2007.903082