作者: Talat Ozden , Bulent G. Akinoglu , Rasit Turan
DOI: 10.1016/J.RENENE.2016.08.045
关键词:
摘要: Abstract Long term outdoor testing of the PV systems at different climatic conditions or under same ambient are extremely important in producing policies for transition to renewables. The present research is three central Anatolia, after four years operation. consist a mono-Si, an a-Si thin film and CdTe arrays. Different calculation procedures input solar irradiation on tilted surface used comparison. Performances together with degradation rates computed using also measured data 20 km away from installed systems. accuracy verified 4 months simultaneous measurements. results showed that aforementioned performances determinant. 44-months-average efficiencies these calculated be 11.86%, 6.40% 5.30%, respectively. obtained as 0.40%, 1.88% 10.60%, Although first two quite similar those appeared literature, system considerably higher than given literature.