Energy Imparted in Roentgen Diagnostic Procedures: Results of Two Surveys during the Periods 1958–1960 and 1974–1976 Related to Technical Modifications

作者: Monica Gustafsson

DOI: 10.1177/028418517902001A19

关键词:

摘要: A comparison of the energy imparted during diagnostic radiographic procedures at University Hospital in Lund 1958 to 1960 and 1974 revealed an unexpected, low decrease intermediate period. The influence various technical factors on irradiation patient was estimated attempts made explain discrepancy between expected measured 1976. Considering growth frequency examinations from 1975 increase population radiology is deduced for that consequences optimum use modifications could have led a decrease.

参考文章(35)
S W Alderson, M Rollins, L H Lanzl, J Spira, An instrumented phantom system for analog computation of treatment plans. American Journal of Roentgenology. ,vol. 87, pp. 185- 195 ,(1962)
Carl Carlsson, Radiation doses from roentgen-diagnostic procedures Springer Berlin Heidelberg. pp. 640- 658 ,(1967) , 10.1007/978-3-642-94994-4_17
D. Schoen, Beziehungen zwischen Flächenionisationswert und Skrotaldosis bei Durchleuchtungen der Thorax- und Abdominalorgane Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren. ,vol. 105, pp. 213- 222 ,(1966) , 10.1055/S-0029-1227962
A. McKinlay, B. McCauley, Spoilt films in x-ray departments. British Journal of Radiology. ,vol. 50, pp. 233- 234 ,(1977) , 10.1259/0007-1285-50-591-233
K. Reinsma, The inherent filtration of x-ray tubes. Radiology. ,vol. 74, pp. 971- 972 ,(1960) , 10.1148/74.6.971
Boldingh Wh, [Graphic determination of primary radiation losses due to incorrect centration & movement of antidiffusing screens]. Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren. ,vol. 89, pp. 233- ,(1958)
E. DALE TROUT, JOHN P. KELLEY, VAUGHN L. LARSON, A comparison of an air gap and a grid in roentgenography of the chest. American Journal of Roentgenology. ,vol. 124, pp. 404- 411 ,(1975) , 10.2214/AJR.124.3.404
G. M. Ardran, H. E. Crooks, Dose in Diagnostic Radiology: The Effect of Changes in Kilovoltage and Filtration British Journal of Radiology. ,vol. 35, pp. 172- 181 ,(1962) , 10.1259/0007-1285-35-411-172
H. Löhr, H. Vogel, J. Reinhart, R. Jantzen, Dosisunterschiede zwischen Röngendiagnostik mit konventionellem Schirmbildgerät und mit einer Bildverstärkerfernsehkette Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren. ,vol. 126, pp. 482- 488 ,(1977) , 10.1055/S-0029-1230622