FIVE YEAR REVIEW OF THE ROTAGLIDE TOTAL KNEE ARTHROPLASTY

作者: C.J. Wilson , B. Fitzgerald , G.R. Tait

DOI: 10.1016/S0968-0160(02)00107-2

关键词:

摘要: Purpose: In this study we intend to evaluate the outcomes of patients with Rotaglide prosthesis implanted for osteoarthritis. Method: All reviewed had primary total knee arthroplasty in Cross-house hospital. The minimum follow up period was 5 years (range 5–8). Patients were assessed clinically and results standardised using Hospital Specialist Surgery (HSS) score. Standard radiographs taken AP lateral planes assess loosening. Case notes then examined evidence complications peri postoperative complications. Results: Sixty seven (73 knees) replacement osteoarthritis. 94% an excellent clinical outcome HSS scores 85 or more. average score 90.2. Two revised, one meniscal fracture dislocation. treated anti-biotics superficial wound infection. Conclusions: We feel offers a safe effective treatment osteoarthritis good at low level complications.

参考文章(8)
John B. Meding, E. Michael Keating, Overview: long-term followup: predicting the success of a total knee arthroplasty. Clinical Orthopaedics and Related Research. ,vol. 388, pp. 7- 9 ,(2001) , 10.1097/00003086-200107000-00003
FREDERICK C. EWALD, The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clinical Orthopaedics and Related Research. ,vol. 248, pp. 9- 12 ,(1989) , 10.1097/00003086-198911000-00003
M. Crova, E. Cenna, C. Olivero, Rotating knee prosthesis Der Orthopäde. ,vol. 29, pp. S43- S44 ,(2000) , 10.1007/PL00003682
A.J. Polyzoides, G.K. Dendrinos, H. Tsakonas, The Rotaglide Total Knee Arthroplasty Prosthesis Design and Early Results Journal of Arthroplasty. ,vol. 11, pp. 453- 459 ,(1996) , 10.1016/S0883-5403(96)80036-2
JOHN N. INSALL, LAWRENCE D. DORR, RICHARD D. SCOTT, W. NORMAN, Rationale of the Knee Society clinical rating system. Clinical Orthopaedics and Related Research. ,vol. 248, pp. 13- 14 ,(1989) , 10.1097/00003086-198911000-00004
JOHN J. CALLAGHAN, JOHN N. INSALL, A. SETH GREENWALD, DOUGLAS A. DENNIS, RICHARD D. KOMISTEK, DAVID W. MURRAY, ROBERT B. BOURNE, CECIL H. RORABECK, LAWRENCE D. DORR, Mobile-bearing knee replacement: concepts and results. Journal of Bone and Joint Surgery, American Volume. ,vol. 50, pp. 1020- 1041 ,(2000) , 10.2106/00004623-200007000-00013
Athanasios C Tsakonas, Apostolos J Polyzoides, Reduction of polyethylene in a congruent meniscal knee prosthesis. Experimental and clinical studies. Acta Orthopaedica Scandinavica. ,vol. 68, pp. 127- 131 ,(1997) , 10.1080/17453674.1997.11744765