A clinical method for estimating the modulus of elasticity of the human cornea in vivo.

作者: David C. Pye

DOI: 10.1371/JOURNAL.PONE.0224824

关键词:

摘要: Background To develop a method, using current clinical instrumentation, to estimate the Young's modulus of human cornea in vivo. Methods Central corneal curvature (CCC), central thickness(CCT), intraocular pressure (IOP) was measured with Goldmann tonometer (IOPG) and Pascal Dynamic Corneal Tonometer(PDCT) one eye 100 normal young subjects (21.07 ± 2.94 years) The Orssengo Pye algorithm used calculate corneas these subjects. Results modulus(E) PDCT IOPG results (Ecalc) 0.25 0.10MPa, without (Eiopg) 0.29 0.06MPa. difference is due tonometry between two instruments, as mean result for 16.89 2.49mmHg 15.06 2.71mmHg. E affected by CCC but more particularly CCT IOP measurements. stiffness are also presented. Conclusion Two methods have been developed vivo instrumentation. One method applicable general condition, Eiopg cornea, can be stiffness.

参考文章(55)
Arthur J. Sit, Shuai-Chun Lin, Arash Kazemi, Jay W. McLaren, Christopher M. Pruet, Xiaoming Zhang, In Vivo Noninvasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study. Journal of Glaucoma. ,vol. 26, pp. 967- 973 ,(2017) , 10.1097/IJG.0000000000000774
Seok Hyun Yun, Dimitri Chernyak, Brillouin microscopy: assessing ocular tissue biomechanics. Current Opinion in Ophthalmology. ,vol. 29, pp. 299- 305 ,(2018) , 10.1097/ICU.0000000000000489
Bruno Zappone, Navinkumar J. Patil, Marco Lombardo, Giuseppe Lombardo, Transient viscous response of the human cornea probed with the Surface Force Apparatus. PLOS ONE. ,vol. 13, ,(2018) , 10.1371/JOURNAL.PONE.0197779
Padmamalini Mahendradas, Mathew Francis, Ruchi Vala, Poornachandra B Gowda, Ankush Kawali, Rohit Shetty, Abhijit Sinha Roy, Quantification of Ocular Biomechanics In Ocular Manifestations of Systemic Autoimmune Diseases. Ocular Immunology and Inflammation. ,vol. 27, pp. 1127- 1137 ,(2019) , 10.1080/09273948.2018.1501491
Lisa Ramm, Robert Herber, Eberhard Spoerl, Lutz E. Pillunat, Naim Terai, Measurement of Corneal Biomechanical Properties in Diabetes Mellitus Using the Ocular Response Analyzer and the Corvis ST Cornea. ,vol. 38, pp. 595- 599 ,(2019) , 10.1097/ICO.0000000000001879
Yu Zhao, Yang Shen, Zhipeng Yan, Mi Tian, Jing Zhao, Xingtao Zhou, Relationship Among Corneal Stiffness, Thickness, and Biomechanical Parameters Measured by Corvis ST, Pentacam and ORA in Keratoconus Frontiers in Physiology. ,vol. 10, pp. 740- ,(2019) , 10.3389/FPHYS.2019.00740
Jun Liu, Cynthia J. Roberts, Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. Journal of Cataract and Refractive Surgery. ,vol. 31, pp. 146- 155 ,(2005) , 10.1016/J.JCRS.2004.09.031
Robert H Small, Qiushi Ren, Jean Marie Parel, Gabriel Simon, Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. Journal of Refractive Surgery. ,vol. 9, pp. 110- 117 ,(1993) , 10.3928/1081-597X-19930301-08
Ahmed Elsheikh, Defu Wang, David Pye, Determination of the modulus of elasticity of the human cornea. Journal of Refractive Surgery. ,vol. 23, pp. 808- 818 ,(2007) , 10.3928/1081-597X-20071001-11