Samarium(III)-PVC-Membrane Sensor Based on Ethoxy-1-ethoxycarbonyl-1,2-dihydroquinoline

作者: Ezzat Naddaf , Hassan Ali Zamani

DOI: 10.1080/00032710902726070

关键词:

摘要: Abstract 2-Ethoxy-1-ethoxycarbonyl-1,2-dihydroquinoline (EED) was found to be a suitable neutral ionophore for the preparation of highly selective samarium (Sm)(III) membrane sensor. Poly vinylchloride (PVC)–based membranes EED with sodium tetraphenyl borate (NaTPB) as an anionic additive and dibutylphthalate (DBP), nitrobenzene (NB), acetophenone (AP) plasticizing solvent mediators were prepared investigated Sm(III) sensors. The sensor exhibited Nernstian response over concentration range 1.0 × 10−6 1.0 × 10−2 M, detection limit 5.0 × 10−7 M. best performance achieved composition 30% PVC, 66% dibutyl phthalate 2% EED, (NaTPB). It has very short time, in whole (∼10s), can used at least 10 weeks. proposed electrode shows good selectivity toward ions wide variety cations, including alkali, alkaline earth, transition-metal, he...

参考文章(61)
Mohammad Reza Abedi, Hassan Ali Zamani, Mohammad Reza Ganjali, Parviz Norouzi, Determination of cerium(III) ions in soil and sediment samples by Ce(III) PVC-based membrane electrode based on 2,5-dioxo-4-imidazolidinyl International Journal of Environmental Analytical Chemistry. ,vol. 88, pp. 353- 362 ,(2008) , 10.1080/03067310701642073
Hassan Ali Zamani, GHADIER Rajabzadeh, Ali Firouz, Mohammad Reza Ganjali, None, Determination of copper(II) in wastewater by electroplating samples using a PVC-membrane copper(II)-selective electrode Journal of Analytical Chemistry. ,vol. 62, pp. 1080- 1087 ,(2007) , 10.1134/S1061934807110135
HASSAN ALIZAMANI, MOHAMMAD REZA GANJALI, Parviz Norouzi, Azadeh Tajarodi, Younes Hanifehpour, FABRICATION OF A COBALT(II) PVC-MEMBRANE SENSOR BASED ON N-(ANTIPYRIDYNIL)-N'-(2-METHOXYPHENYL)THIOUREA Journal of The Chilean Chemical Society. ,vol. 52, pp. 1332- 1337 ,(2007) , 10.4067/S0717-97072007000400015
Hassan Ali Zamani, Mohammad Reza Ganjali, Masoud Salavati-Niasari, Fabrication of an iron(III)-selective PVC membrane sensor based on a bis-bidentate Schiff base ionophore Transition Metal Chemistry. ,vol. 33, pp. 995- 1001 ,(2008) , 10.1007/S11243-008-9142-3
Majed Mohammadhossieni, Hassan Ali Zamani, Mehdi Nekoei, Terbium(III) Ion-Selective Electrochemical Sensor Based on Hematoporphyrin Analytical Letters. ,vol. 42, pp. 298- 311 ,(2009) , 10.1080/00032710802585675
Hassan Ali Zamani, Mahbobeh Masrournia, Sara Sahebnasagh, Mohammad Reza Ganjali, Fabrication of a Praseodymium(III) PVC-Membrane Sensor Based on N′1,N′2-Bis(2-oxo-1,2-diphenylethylidene) ethanedihydrazide Analytical Letters. ,vol. 42, pp. 555- 570 ,(2009) , 10.1080/00032710802677092