作者: Edvins Terehovics , Ivars Veidenbergs , Dagnija Blumberga
DOI: 10.1016/J.EGYPRO.2017.04.053
关键词:
摘要: Abstract An exergy factor analysis of the Ludza city district heating system (DHS) in Latvia is performed research paper. Calculated results are analysed order to understand which parameters mostly affect factor. The algorithm for network elaborated and evaluated. From calculations, it can be concluded that case decreasing ambient temperature, supply temperature rises leads increasing compared with similar other countries.