Allergic reaction to titanium-made fixed dental restorations: A clinical report .

作者: Nagakazu Ko , Atsushi Mine , Hiroshi Egusa , Tsunetoshi Shimazu , Rieko Ko

DOI: 10.1111/JOPR.12136

关键词:

摘要: From the mid 1980s (approximately 10 years after titanium was first used as a medical metal), reports of suspected Ti sensitization began to emerge. In present report,a 33-year-old Japanese woman presented with pruritus fingers and specific reaction mercury, nickel, silver on lymphocyte stimulation testing (LST).Her condition improved 17 restorations containing Hg or Ag were removed.Titanium composite resin, both which had no LST, in replacements intraoral restoration improved; however, cervical eczema emerged 9 months, repeat LST showed Ti. The removal titanium. It is therefore likely that allergy provoked eczema. This report suggests clinicians should be aware possibility from dental restoration.

参考文章(12)
Frank Muschter, Tomasz Gedrange, Winfried Harzer, Anke Schröter, Sensitivity of titanium brackets to the corrosive influence of fluoride-containing toothpaste and tea. Angle Orthodontist. ,vol. 71, pp. 318- 323 ,(2009) , 10.1043/0003-3219(2001)071<0318:SOTBTT>2.0.CO;2
Arne Hensten-Pettersen, Casting alloys: side-effects. Advances in Dental Research. ,vol. 6, pp. 38- 43 ,(1992) , 10.1177/08959374920060011401
David F. Williams, Titanium as a metal for implantation. Part 2: biological properties and clinical applications. Journal of Medical Engineering & Technology. ,vol. 1, pp. 266- 270 ,(1977) , 10.3109/03091907709162192
Hiroshi Egusa, Nagakazu Ko, Tsunetoshi Shimazu, Hirofumi Yatani, Suspected association of an allergic reaction with titanium dental implants: A clinical report Journal of Prosthetic Dentistry. ,vol. 100, pp. 344- 347 ,(2008) , 10.1016/S0022-3913(08)60233-4
Margot S. Peters, Arnold L. Schroeter, Harriet M. van Hale, James C. Broadbent, Pacemaker contact sensitivity Contact Dermatitis. ,vol. 11, pp. 214- 218 ,(1984) , 10.1111/J.1600-0536.1984.TB00986.X
Mauno Könönen, Juha Rintanen, Antii Waltimo, Pentti Kempainen, Titanium framework removable partial denture used for patient allergic to other metals: A clinical report and literature review The Journal of Prosthetic Dentistry. ,vol. 73, pp. 4- 7 ,(1995) , 10.1016/S0022-3913(05)80264-1
Mauno H.O. Könönen, Eeva T. Lavonius, Jorma K. Kivilahti, SEM observations on stress corrosion cracking of commercially pure titanium in a topical fluoride solution Dental Materials. ,vol. 11, pp. 269- 272 ,(1995) , 10.1016/0109-5641(95)80061-1
Yohsuke Taira, Tetsuro Odatsu, Takashi Sawase, Effects of a fluoride etchant and a phosphate primer on bonding of veneering composite to Ti-6Al-4V alloy for CAD/CAM restorations. Journal of Prosthodontic Research. ,vol. 57, pp. 30- 35 ,(2013) , 10.1016/J.JPOR.2012.08.002