Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: a 4-year single-center follow-up.

作者: Thomas Umscheid , Wolf J. Stelter

DOI: 10.1583/1074-6218(1999)006<0017:TRAISP>2.0.CO;2

关键词:

摘要: Purpose:To report the nature and ramifications of structural positional changes over time in tube modular bifurcated aortic stent-grafts.Methods:Two hundred ninety-one patients received endovascular grafts (primarily Stentor/Vanguard) between August 1994 1998. Follow-up surveillance (clinical laboratory examination, biplanar noncontrast radiography, contrast-enhanced computed tomography) has been maintained on all for 4 years. Changes configuration position endografts have noted their sequelae charted.Results:Three types endograft shape documented: mild — slight distortions visible plain radiographs (n = 90, 31.0%), significant angulations reaching 60° to 90° 65, 22.3%), severe ≥ 10, 3.4%). never gave rise late migration at proximal attachment site, whereas distal ends, easily retracted from iliac arteries 8). Structural altera...

参考文章(20)
Geoffrey H. White, Weiyun Yu, James May, Richard Waugh, Xavier Chaufour, John P. Harris, Michael S. Stephen, Three-Year Experience with the White-Yu Endovascular GAD Graft for Transluminal Repair of Aortic and Iliac Aneurysms Journal of Endovascular Therapy. ,vol. 4, pp. 124- 136 ,(1997) , 10.1583/1074-6218(1997)004<0124:TYEWTW>2.0.CO;2
Timothy Resch, Krassi Ivancev, Mats Lindh, Ulf Nyman, Jan Brunkwall, Martin Malina, Bengt Lindblad, Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter Journal of Vascular Surgery. ,vol. 28, pp. 242- 249 ,(1998) , 10.1016/S0741-5214(98)70160-0
Geert Maleux, Hervé Rousseau, Philippe Otal, Daniel Colombier, Yves Glock, Francis Joffre, Modular component separation and reperfusion of abdominal aortic aneurysm sac after endovascular repair of the abdominal aortic aneurysm: A case report Journal of Vascular Surgery. ,vol. 28, pp. 349- 352 ,(1998) , 10.1016/S0741-5214(98)70172-7
Mathias Langer, Ulrich Blum, Götz Voshage, Friedhelm Beyersdorf, Dirck Töllner, Gerhard Spillner, Andreas Morgenroth, Gudrun Nagel, Christian Schlensack, Two-center German experience with aortic endografting. Journal of Endovascular Therapy. ,vol. 4, pp. 137- 146 ,(1997) , 10.1583/1074-6218(1997)004<0137:TCGEWA>2.0.CO;2
Claude Mialhe, Claude Amicabile, Jean Pierre Becquemin, Endovascular treatment of infrarenal abdominal aneurysms by the Stentor system: Preliminary results of 79 cases Journal of Vascular Surgery. ,vol. 26, pp. 199- 209 ,(1997) , 10.1016/S0741-5214(97)70180-0
Lars Norgren, Bengt Jernby, Lena Engellau, Aortoenteric fistula caused by a ruptured stent-graft: a case report. Journal of Endovascular Surgery. ,vol. 5, pp. 269- 272 ,(1998) , 10.1583/1074-6218(1998)005<0269:AFCBAR>2.0.CO;2
R. Balm, B.C. Eikelboom, J. May, P.R.F. Bell, J. Swedenborg, J. Collin, Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms European Journal of Vascular and Endovascular Surgery. ,vol. 11, pp. 214- 220 ,(1996) , 10.1016/S1078-5884(96)80055-4
Wesley S. Moore, Robert B. Rutherford, EVT Investigators, Transfemoral endovascular repair of abdominal aortic aneurysm: Results of the North American EVT phase 1 trial Journal of Vascular Surgery. ,vol. 23, pp. 543- 553 ,(1996) , 10.1016/S0741-5214(96)80032-2
James May, Geoffrey H. White, Weiyun Yu, Richard Waugh, Michael S. Stephen, Kishore Sieunarine, Xavier Chaufour, John P. Harris, Endoluminal repair of abdominal aortic aneurysms: Strengths and weaknesses of various prostheses observed in a 4.5-year experience Journal of Endovascular Surgery. ,vol. 4, pp. 147- 151 ,(1997) , 10.1583/1074-6218(1997)004<0147:EROAAA>2.0.CO;2
Juan C. Parodi, Frank J. Criado, Hector D. Barone, Claudio Schönholz, Luis A. Queral, Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: A progress report Annals of Vascular Surgery. ,vol. 8, pp. 523- 529 ,(1994) , 10.1007/BF02017407