An augmented reality system for image-guided surgery

作者: R. Marmulla , H. Hoppe , J. Mühling , G. Eggers

DOI: 10.1016/J.IJOM.2005.05.004

关键词:

摘要: The introduced new developed navigation system is a High Intensity Approach Light System for augmented reality in image-guided surgery. surgeon follows the projected approach lights with his ordinary surgical instruments. Thus, tracked instruments are not necessary this system.

参考文章(13)
Matthew A. Howard, Matthew B. Dobbs, Tereasa M. Simonson, William E. LaVelle, Mark A. Granner, Noninvasive, reattachable skull fiducial marker system Journal of Neurosurgery. ,vol. 83, pp. 372- 376 ,(1994) , 10.3171/JNS.1995.83.2.0372
R. Heermann, P. R. Issing, H. Husstedt, H. Becker, T. Lenarz, Einsatz des Navigationssystems MKM® im Bereich der lateralen Schädelbasis1 Laryngo-Rhino-Otologie. ,vol. 80, pp. 569- 575 ,(2001) , 10.1055/S-2001-17839
Rüdiger Marmulla, Harald Hoppe, Joachim Mühling, Georg Eggers, High intensity approach light system in image-guided surgery International Congress Series. ,vol. 1281, pp. 543- 547 ,(2005) , 10.1016/J.ICS.2005.03.005
Jos Claes, Erwin Koekelkoren, Floris L. Wuyts, Gerd M. E. Claes, Luc Van den Hauwe, Paul H. Van de Heyning, Accuracy of computer navigation in ear, nose, throat surgery: the influence of matching strategy. Archives of Otolaryngology-head & Neck Surgery. ,vol. 126, pp. 1462- 1466 ,(2000) , 10.1001/ARCHOTOL.126.12.1462
Stefan Haßfeld, Joachim Mühling, Joachim Zöller, Intraoperative navigation in oral and maxillofacial surgery International Journal of Oral and Maxillofacial Surgery. ,vol. 24, pp. 111- 119 ,(1995) , 10.1016/S0901-5027(05)80871-9
M. Cartellieri, F. Vorbeck, J. Kremser, Comparison of Six Three-dimensional Navigation Systems During Sinus Surgery Acta Oto-Laryngologica. ,vol. 121, pp. 500- 504 ,(2001) , 10.1080/00016480120004
J.M. Fitzpatrick, J.B. West, The distribution of target registration error in rigid-body point-based registration IEEE Transactions on Medical Imaging. ,vol. 20, pp. 917- 927 ,(2001) , 10.1109/42.952729
R Marmulla, T Lüth, J Mühling, S Hassfeld, None, Automated laser registration in image-guided surgery: evaluation of the correlation between laser scan resolution and navigation accuracy. International Journal of Oral and Maxillofacial Surgery. ,vol. 33, pp. 642- 648 ,(2004) , 10.1016/J.IJOM.2004.01.005
S. Hassfeld, A. Göggelmann, M. Nesper, T. Wetter, T. Lutze, M. Fischer, J. Kozak, Semiautomated registration using new markers for assessing the accuracy of a navigation system Computer Aided Surgery. ,vol. 7, pp. 11- 24 ,(2002) , 10.1002/IGS.10030
Andreas Rüdiger Gunkel, Wolfgang Freysinger, Walter Franz Thumfart, Experience with various 3-dimensional navigation systems in head and neck surgery. Archives of Otolaryngology-head & Neck Surgery. ,vol. 126, pp. 390- 395 ,(2000) , 10.1001/ARCHOTOL.126.3.390