Integrated ethanol biosensors based on carbon paste electrodes modified with [Re(phen-dione)(CO)3Cl] and [Fe(phen-dione)3](PF6)2

作者: F Tobalina , F Pariente , L Hernández , H.D Abruña , E Lorenzo

DOI: 10.1016/S0003-2670(99)00332-3

关键词:

摘要: Abstract The preparation and electrochemical characterization of carbon paste electrodes modified with 1,10-phenantroline-5,6-dione (phen-dione) complexes Fe ([Fe(phen-dione)3]2+) Re ([Re(phen-dione)(CO)3Cl]) as well their behavior electrocatalysts towards the oxidation NADH are described. These exhibit redox responses very similar to those in aqueous solution, including pH-dependent response ascribed pendant o-quinone groups, observed for films electrodeposited onto glassy electrodes. Carbon either complexes, exhibited potent persistent electrocatalytic activity at potentials around 0.0 V versus SSCE, which represents a dramatic diminution overpotential. Using complex, alcohol dehydrogenase NAD+ we have developed an integrated ethanol biosensor. It detection limit 45 μM (S/N = 3), linearity up 4.0 mM, sensitivity 174 nA mM−1 stability least 8 days when stored 4°C.

参考文章(42)
Hans Ulrich Bergmeyer, Methods of Enzymatic Analysis ,(1963)
Maria Hedenmo, Arántzazu Narváez, Elena Domínguez, Ioanis Katakis, Reagentless amperometric glucose dehydrogenase biosensor based on electrocatalytic oxidation of NADH by osmium phenanthrolinedione mediator Analyst. ,vol. 121, pp. 1891- 1895 ,(1996) , 10.1039/AN9962101891
Chihiro. Ueda, Daniel Chi-Sing. Tse, Theodore. Kuwana, Stability of catechol modified carbon electrodes for electrocatalysis of dihydronicotinamide adenine dinucleotide and ascorbic acid Analytical Chemistry. ,vol. 54, pp. 850- 856 ,(1982) , 10.1021/AC00243A003
Joseph Wang, Najih Naser, Modified carbon-wax composite electrodes Analytica Chimica Acta. ,vol. 316, pp. 253- 259 ,(1995) , 10.1016/0003-2670(95)00367-9
S. Sakura, R.P. Buck, Amperometric processes with glucose oxidase embedded in the electrode Bioelectrochemistry and Bioenergetics. ,vol. 28, pp. 387- 400 ,(1992) , 10.1016/0302-4598(92)80027-E
Joseph. Wang, Kurian. Varughese, Polishable and robust biological electrode surfaces Analytical Chemistry. ,vol. 62, pp. 318- 320 ,(1990) , 10.1021/AC00202A019
Julie Wangsa, Neil D. Danielson, Electrochemical detection for high-performance liquid chromatography using a Kel-F wax-graphite electrode Journal of Chromatography A. ,vol. 514, pp. 171- 178 ,(1990) , 10.1016/S0021-9673(01)89388-2
Ioanis Katakis, Elena Dom�nguez, Catalytic electrooxidation of NADH for dehydrogenase amperometric biosensors Mikrochimica Acta. ,vol. 126, pp. 11- 32 ,(1997) , 10.1007/BF01242656
Q. Wu, M. Maskus, F. Pariente, F. Tobalina, V. M. Fernández, E. Lorenzo, H. D. Abruña, Electrocatalytic Oxidation of NADH at Glassy Carbon Electrodes Modified with Transition Metal Complexes Containing 1,10-Phenanthroline-5,6-dione Ligands Analytical Chemistry. ,vol. 68, pp. 3688- 3696 ,(1996) , 10.1021/AC960395Y