Dental implant design–effect on bone remodeling

作者: R. M. Pilliar , D. A. Deporter , P. A. Watson , N. Valiquette

DOI: 10.1002/JBM.820250405

关键词:

摘要: … for both the threaded and partially porous-coated implants while no significant bone loss was seen with fully porous-coated implants in the absence of plaque-associated infection. It is …

参考文章(20)
D.A. Deporter, B. Friedland, P.A. Watson, R.M. Pilliar, T.P. Howley, D. Abdulla, A.H. Melcher, D.C. Smith, A Clinical and Radiographic Assessment of a Porous-surfaced, Titanium Alloy Dental Implant System in Dogs Journal of Dental Research. ,vol. 65, pp. 1071- 1077 ,(1986) , 10.1177/00220345860650080601
Larry J. Peterson, Ralph V. McKinney, Billy M. Pennél, Jerome J. Klawitter, Allan M. Weinstein, Clinical, Radiographic, and Histological Evaluation of Porous Rooted Cobalt-Chromium Alloy Dental Implants: Journal of Dental Research. ,vol. 59, pp. 99- 108 ,(1980) , 10.1177/00220345800590022001
D.A. Deporter, P.A. Watson, R.M. Pilliar, M.L. Chipmani, N. Valiquette, A Histological Comparison in the Dog of Porous-coated vs. Threaded Dental Implants Journal of Dental Research. ,vol. 69, pp. 1138- 1145 ,(1990) , 10.1177/00220345900690050401
T. A. LARHEIM, H. WIE, K. TOLO, O. FAEHN, H. R. HAANAES, J. ODEGAARD, Comparison of bone resorption at one-step and two-step mandibular endosseous implants in dogs. European Journal of Oral Sciences. ,vol. 92, pp. 84- 87 ,(1984) , 10.1111/J.1600-0722.1984.TB00862.X
S. D. Cook, J. J. Klawitter, A. M. Weinstein, The influence of implant elastic modulus on the stress distribution around LTI carbon and aluminum oxide dental implants Journal of Biomedical Materials Research. ,vol. 15, pp. 879- 887 ,(1981) , 10.1002/JBM.820150612
R.M. Rose, R.B. Martin, R.B. Orr, E.L. Radin, Architectural changes in the proximal femur following prosthetic insertion: preliminary observations of an animal model. Journal of Biomechanics. ,vol. 17, pp. 241- 249 ,(1984) , 10.1016/0021-9290(84)90135-0
S.D. Cook, J.J. Klawitter, A.M. Weinstein, A Model for the Implant-Bone Interface Characteristics of Porous Dental Implants Journal of Dental Research. ,vol. 61, pp. 1006- 1009 ,(1982) , 10.1177/00220345820610080201
R. M. Pilliar, H. U. Cameron, A. G. Binnington, J. Szivek, I. Macnab, Bone ingrowth and stress shielding with a porous surface coated fracture fixation plate Journal of Biomedical Materials Research. ,vol. 13, pp. 799- 810 ,(1979) , 10.1002/JBM.820130510
C.J. Lavernia, S.D. Cook, A.M. Weinstein, J.J. Klawitter, An analysis of stresses in a dental implant system Journal of Biomechanics. ,vol. 14, pp. 555- 560 ,(1981) , 10.1016/0021-9290(81)90005-1
R. M. Pilliar, R. Vowles, D. F. Williams, Note: Fracture toughness testing of biomaterials using a mini‐short rod specimen design Journal of Biomedical Materials Research. ,vol. 21, pp. 145- 154 ,(1987) , 10.1002/JBM.820210116