Quantification of Nerve Fiber Layer Thickness in Normal and Glaucomatous Eyes Using Optical Coherence Tomography

作者: Joel S. Schuman

DOI: 10.1001/ARCHOPHT.1995.01100050054031

关键词:

摘要: Purpose: Quantitative assessment of nerve fiber layer (NFL) thickness in normal and glaucomatous eyes, correlation with conventional measurements the optic structure function. Methods: We studied 59 eyes 33 subjects by ophthalmologic physical examination, Humphrey 24-2 visual fields, stereoscopic head photography, optical coherence tomography. Results: Nerve as measured tomography demonstrated a high degree functional status nerve, field examination ( P =.0001). Neither cupping nor neuroretinal rim area were strongly associated loss was NFL =.17 =.21,respectively). Cupping correlated only when cup small (cup-to-diameter ratio, 0.1 to 0.3) or large 0.8 1.0) =.006); there no between otherwise. layer, especially inferior quadrant, significantly thinner than =.04). Finally, we found decrease aging, even controlling for factors diagnosis glaucoma =.03). Conclusions: can be using These provide good structural known parameters.

参考文章(27)
D Huang, E. Swanson, C. Lin, J. Schuman, W. Stinson, W Chang, M. Hee, T Flotte, K Gregory, C. Puliafito, al. et, Optical coherence tomography Science. ,vol. 254, pp. 1178- 1181 ,(1991) , 10.1126/SCIENCE.1957169
George A. Cioffi, Alan L. Robin, Roger D. Eastman, Howard F. Perell, Faith A. Sarfarazi, Shalom E. Kelman, Confocal laser scanning ophthalmoscope. Reproducibility of optic nerve head topographic measurements with the confocal laser scanning ophthalmoscope. Ophthalmology. ,vol. 100, pp. 57- 62 ,(1993) , 10.1016/S0161-6420(93)31693-3
Josef F. Bille, Andreas W. Dreher, Gerhard Zinser, Scanning Laser Tomography of the Living Human Eye Noninvasive Diagnostic Techniques in Ophthalmology. pp. 528- 547 ,(1990) , 10.1007/978-1-4613-8896-8_28
J Caprioli, J M Miller, Videographic measurements of optic nerve topography in glaucoma. Investigative Ophthalmology & Visual Science. ,vol. 29, pp. 1294- 1298 ,(1988)
Donald F. Morrison, Multivariate statistical methods Published in <b>1976</b> in New York NY) by McGraw-Hill. ,(1976)
Lichter Pr, Variability of expert observers in evaluating the optic disc. Transactions of the American Ophthalmological Society. ,vol. 74, pp. 532- 572 ,(1976)
Robert H. Webb, George W. Hughes, Francois C. Delori, Confocal scanning laser ophthalmoscope Applied Optics. ,vol. 26, pp. 1492- 1499 ,(1987) , 10.1364/AO.26.001492
Joseph A Izatt, Michael R Hee, Eric A Swanson, Charles P Lin, David Huang, Joel S Schuman, Carmen A Puliafito, James G Fujimoto, Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography Archives of Ophthalmology. ,vol. 112, pp. 1584- 1589 ,(1994) , 10.1001/ARCHOPHT.1994.01090240090031
A.G. Balazsi, J. Rootman, S.M. Drance, M. Schulzer, G.R. Douglas, The Effect of Age on the Nerve Fiber Population of the Human Optic Nerve American Journal of Ophthalmology. ,vol. 97, pp. 760- 766 ,(1984) , 10.1016/0002-9394(84)90509-9
Robert N Weinreb, Andreas W Dreher, Anne Coleman, Harry Quigley, Blake Shaw, Klaus Reiter, Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer Thickness Archives of Ophthalmology. ,vol. 108, pp. 557- 560 ,(1990) , 10.1001/ARCHOPHT.1990.01070060105058