A validation study for estimation of femoral anteversion using the posterior lesser trochanter line: an analysis of computed tomography measurement.

作者: Ho Hyun Yun , Jung Ro Yoon , Jae-Hyuk Yang , Seung Yeop Song , Sung Bum Park

DOI: 10.1016/J.ARTH.2012.10.023

关键词:

摘要: The aim of this study was to introduce a simple and reliable intraoperative reference guide reproduce the normal femoral anteversion during total hip arthroplasty (THA). We hypothesized that posterior lesser trochanter line (PLTL) could be useful for estimating THA. conducted 56 men (112 hips) evaluate relationship between PLTL using computed tomography scans. mean 9.0° ± 8.1° (range, -16.2° 32.9°). angle correlated (r(2) = 0.12, P < 0.05) with anteversion. found constant anteversion, may used as stem fixation.

参考文章(41)
Kuen Tak Suh, Jeong Han Kang, Hyoung Lok Roh, Kyu Pill Moon, Hak Jin Kim, True Femoral Anteversion During Primary Total Hip Arthroplasty The Journal of Arthroplasty. ,vol. 21, pp. 599- 605 ,(2006) , 10.1016/J.ARTH.2005.04.042
JAMES R. MACKENZIE, SCOTT S. KELLEY, RICHARD C. JOHNSTON, Total hip replacement for coxarthrosis secondary to congenital dysplasia and dislocation of the hip : long-term results Journal of Bone and Joint Surgery, American Volume. ,vol. 78, pp. 55- 61 ,(1996) , 10.2106/00004623-199601000-00008
Masahiro Hasegawa, Mitsuhito Komeno, Akihiro Sudo, Atsumasa Uchida, Computed tomographic evaluation of component position on dislocation after total hip arthroplasty. Orthopedics. ,vol. 29, pp. 1104- 1108 ,(2006) , 10.3928/01477447-20061201-05
Maruyama M, Feinberg, Capello Wn, D'Antonio Ja, The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clinical Orthopaedics and Related Research. pp. 52- 65 ,(2001)
Mamed Mesgarzadeh, George Revesz, Akbar Bonakdarpour, Femoral neck torsion angle measurement by computed tomography. Journal of Computer Assisted Tomography. ,vol. 11, pp. 799- 803 ,(1987) , 10.1097/00004728-198709000-00011
Kuiwon Choi, Gon Khang, Jong Soo Yang, Tae-Soo Bae, Cheol-Sang Kim, A study of Korean femoral geometry. Clinical Orthopaedics and Related Research. ,vol. 406, pp. 116- 122 ,(2003) , 10.1097/01.BLO.0000030502.43495.C1
I. A. Karnezis, A technique for accurate reproduction of the femoral anteversion during primary total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. ,vol. 121, pp. 343- 345 ,(2001) , 10.1007/S004020000237
J. H. Kellgren, J. S. Lawrence, Radiological Assessment of Osteo-Arthrosis Annals of the Rheumatic Diseases. ,vol. 16, pp. 494- 502 ,(1957) , 10.1136/ARD.16.4.494
Siân E.M. Jenkins, Marian E. Harrington, Amy B. Zavatsky, John J. O'Connor, Tim N. Theologis, Femoral muscle attachment locations in children and adults, and their prediction from clinical measurement Gait & Posture. ,vol. 18, pp. 13- 22 ,(2003) , 10.1016/S0966-6362(02)00137-6
Svein Anda, Terje Terjesen, Kjell Arne Kvistad, Svein Svenningsen, Acetabular angles and femoral anteversion in dysplastic hips in adults: CT investigation Journal of Computer Assisted Tomography. ,vol. 15, pp. 115- 120 ,(1991) , 10.1097/00004728-199101000-00018