The Metal/Polyethylene Interface

作者: J. L. Tipper , A. A. Besong , H. Minakawa , M. H. Stone , B. M. Wroblewski

DOI: 10.1007/978-1-4471-0477-3_10

关键词:

摘要: Total hip replacements have been used for over 30 years with considerable success. Approximately 50,000 joints are replaced each year in the UK, and world-wide that figure rises to approximately 800,000. Today most common type of prostheses implanted comprises a highly polished metallic femoral head which articulates against an ultra high molecular weight polyethylene (UHMWPE) acetabular cup. In early 1960s Sir John Charnley pioneered low friction arthroplasty technique, introduction UHMWPE as bearing surface acetabulum has allowed total joint become commonplace operation it is today

参考文章(45)
J FISHER, E. A REEVES, G. H ISAAC, K. A SAUM, W. M SANFORD, Comparison of the wear of aged and non-aged ultrahigh molecular weight polyethylene sterilized by gamma irradiation and by gas plasma. Journal of Materials Science: Materials in Medicine. ,vol. 8, pp. 375- 378 ,(1997) , 10.1023/A:1018537001366
J.L. Hailey, E. Ingham, M. Stone, B.M. Wroblewski, J. Fisher, A.A. Besong, A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE Bio-medical Materials and Engineering. ,vol. 7, pp. 59- 65 ,(1997) , 10.3233/BME-1997-7105
AS Shanbhag, JJ Jacobs, TT Glant, JL Gilbert, J Black, JO Galante, Composition and morphology of wear debris in failed uncemented total hip replacement Journal of Bone and Joint Surgery-british Volume. ,vol. 76, pp. 60- 67 ,(1994) , 10.1302/0301-620X.76B1.8300684
B Weightman, SA Swanson, GH Isaac, BM Wroblewski, Polyethylene wear from retrieved acetabular cups Journal of Bone and Joint Surgery-british Volume. ,vol. 73, pp. 806- 810 ,(1991) , 10.1302/0301-620X.73B5.1894671
J L Hailey, E Ingham, M Stone, B M Wroblewski, J Fisher, Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests ; the influence of counterface roughness Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. ,vol. 210, pp. 3- 10 ,(1996) , 10.1243/PIME_PROC_1996_210_385_02
DAVID W. MURRAY, N. RUSHTON, Mediators of bone resorption around implants. Clinical Orthopaedics and Related Research. pp. 295- 304 ,(1992) , 10.1097/00003086-199208000-00043
JOHN CHARNLEY, DAVID K. HALLEY, Rate of wear in total hip replacement. Clinical Orthopaedics and Related Research. ,vol. 112, pp. 170- 179 ,(1975) , 10.1097/00003086-197510000-00021
Philip Stashenko, Floyd E. Dewhirst, Monique L. Rooney, Laurie A. Desjardins, John D. Heeley, Interleukin‐1β is a potent inhibitor of bone formation in vitro Journal of Bone and Mineral Research. ,vol. 2, pp. 559- 565 ,(2009) , 10.1002/JBMR.5650020612